Do all for safety,for a safe world!

Fixed Aerosol Wind Turbine Fire Suppression Systems

» Products » Minisol Aerosol Fire Extinguisher » Fixed Aerosol Wind Turbine Fire Suppression Systems
  • Fixed Aerosol Wind Turbine Fire Suppression Systems

    CATEGORY AND TAGS:
    Minisol Aerosol Fire Extinguisher, Products

    aerosol suppression system is an automatic fire extinguishing solution for wind turbines and their Corresponding distribution cabinets.

    enquiry
    • Specifications
    • Features
    • Application
    • More Matters

    What type of fire extinguisher could be a better wind turbine fire suppression system? The answer, of course, is the aerosol fire extinguisher. Please listen to our detailed explanation for you.

    The wind turbines, nacelle is a large enclosed space and is a compartment used to accommodate and protect the main shaft, gearbox, generator, and other transmission systems of wind turbines, as well as other electrical equipment.

    The various electrical equipment and precision components in the wind turbine cabin are high-tech and expensive.

    Moreover, wind farms are generally located in harsh environments such as grasslands, mountains, or oceans, and wind turbine cabins are usually unmanned.

    So if a fire occurs in the wind turbine nacelle due to overheating or other reasons, the consequences are devastating.

    Fixed aerosol fire extinguishers can be well installed in wind turbine cabins for the following reasons:

    • There are many electronic components in the wind turbine cabin, and there is not much-remaining space. It is required that the installed fire extinguishers be of small size, and the aerosol fire extinguisher is a small dimension product.
    • The extinguishing efficiency of an aerosol generator is extremely high, and a 3000-gram aerosol agent can almost cover the entire cabin space.
    • Aerosol fire extinguishers are environmentally friendly and will not damage the precision instruments and high-value equipment in the wind turbine room after spraying.

    thermo bulb aeroso fire extinguisher

    Specification of Fixed-Type Aerosol Wind Turbine Fire Suppression Device

    The following are the specific specifications of a 3000 grams aerosol fire extinguishing device for wind turbine cabins:

    • Product Model: 3000ST.
    • Product Function: Wind turbine fire suppression.
    • Trigger Mode: thermo bulb, temperature range from 57 to 141 degrees Celsius.
    • Thermo glass brand: Job Brand from Germany.
    • Dimension: The diameter is 21.8 centimeters and the height is 29.5 centimeters.
    • Concentration of Aerosol Compound: 100 grams per cubic meter.
    • Cover Area: 30 cubic meters.
    • The Quality of Aerosol Compound: 3 kilograms.
    • The Main Material of the Outer Cylinder: is SUS 304 stainless steel.
    • Product Gross Weight: 12.5 kilograms.
    • Spraying Time: 36 to 38 seconds.
    • Lifetime: 10 years.
    • Installation method: horizontally or vertically.
    • Certificates and approvals: CE, Rhos, IP67, GL, CSC, etc.

    Note: There are also distribution cabinets (control panels) in the wind turbine nacelles and tower base. Which model is better to install in the distribution cabinet (control panels)? Please refer to this page – Mini Aerosol Suppression System for Control Panels.

     

    This wind turbine nacelle aerosol fire extinguisher has many features, some of which are listed below:

    • its design density is 100 grams per cubic meter, it almost can suppress fire in a 30 cubic meters confined space.
    • Aerosol agents are non-corrosive and will not corrode wind turbine nacelle and distribution cabinet facilities.
    • It works automatically and does not require any people to operate over there.
    • Furthermore, after releasing, it causes little residue, then is no need to sweep up the wind nacelle cabin.
    • Its shell is made of 304 stainless steel, with a protection level of IP67, which is both waterproof and moisture-proof.

    This 3000 grams aerosol agent fire suppression system not only applies in wind turbines but also in more places:

    • Generator room.
    • Power distribution room.
    • Various types of vehicles.
    • Various cabinets, and control panels.
    • Sea vessel engine room.
    • Computer room.
    • Data center room.
    • Bank vaults.
    • Power supply room.
    • Low and high voltage room.

    Transport personnel, operators, and installers are advised to pay attention to the following matters:

    • Special protective measures need to be taken for JOB brand glass bulbs during product transportation, and the glass bulbs should be individually packaged with sponges.
    • The product is a 9.1-level hazardous material, and specialized export certification is required for sea and air transportation. But there are no restrictions on vehicle transportation.
    • During the transportation process, operators should handle it with care.
    • Please store in an environment below 50 degrees Celsius and maintain ventilation.
    • Please refer to the instruction manual for specific details.

    Enquiry Form ( we will get back you as soon as possible )

    Name:
    *
    Email:
    *
    Message:

    Verification:
    5 + 9 = ?