Gör allt för säkerhets skull,för en säker värld!

Inergen IG541 brandsläckningssystem

» Produkter » IG541 brandskyddssystem » Inergen IG541 Fire Suppression System
  • Inergen IG541 brandsläckningssystem

    KATEGORI OCH TAGGAR:
    IG541 brandskyddssystem, Produkter

    Inergen IG541 fire suppression is an environmentally friendly fire extinguishing system and non-toxic, non-flammable, can be used for a wide range of fire protection and suppression, it is suitable for fire class of solid combustibles fire, flammable liquids fire, and gas fire, and electrical equipment fire.

    förfrågan
    • Specifikationer
    • Funktioner
    • Ansökan
    • Mer information

    Similar to the CO2 suppression system, The Inergen IG541 fire suppression system is a clean agent fire protection and extinguishing system which is a mixture of argon, kväve, and CO2, contains 52% kväve, 40% argon, och 8% koldioxid; so hereby we called the Inergen as “IG541”.

    It uses inert gas to dilute the concentration of oxygen in the combustion reaction zone.

    Inergen is perfect in performance, cost-effective, and environmentally friendly.

    Inergen IG-541 is colorless, luktfri, and electrically non-conductive with a density approximately the same as air.

    It is used for fire classes A, B, C eld, and E.

    fire extinguishing systems inert gas

    BELOW LIST HERE IS THE BASIC PARAMETERS OF IG541 SYSTEM:

    • Model Number.: QMH15 (volume of the storage cylinder).
    • Extinguishing Agent: Nitrogen 52%, Argon 40%, Koldioxid 8%.
    • Volume of the Storage cylinder: 70l, 80L, 90L.
    • IG541 Agent Storage Pressure: 15MPa(20 degrees centigrade).
    • Max Operation Voltage: 17.2 MPa.
    • IG541 Agent Refilling Concentration: 0.2115kg/L. (the density).
    • Activation Electric Power: backup power at DC24V,3A, Main power at 220V, 50HZ.
    • Fire Suppression Style: Total översvämning.
    • Fire Discharging Time: 60 sekunder.
    • Activation Type: electrics, Mechanical, and manual.
    • Driving Gas: Nitrogen gas.
    • Driving Gas Refilling Pressure: 6 MPa(20 degrees centigrade).
    • Operation Temperature: 0 till 50 degrees centigrade.
    • Relativ luftfuktighet: 95%±3%.
    • Discharging Delay Time: 30 seconds adjustable.

    The inert gas IG541, as a mixed gas fire extinguishing system, combines the characteristics and advantages of several gases:

    • Eco-friendly products with clean agents.
    • The ozone depletion potential value is zero.
    • The global warming potential value is zero.
    • The atmospheric lifetime is very low.
    • Not cause any fog when discharging.
    • Safe for occupied areas.
    • No decomposition products.
    • Remote storage of agent.
    • Directional valve systems.
    • Storage at a pressure of 300 bar.
    • Have no residue after discharging.
    • Don't need to clean up after discharging.
    • Both total flooding and local application.

    Although it is not as popular as the hepta-fluoro propane fire extinguishing system, it can be installed in some places:

    • Arkiv, library, museer, campus.
    • Hospitals, schools, universities, healthcare centers, and major medical facilities.
    • High-rise building and super-market.
    • Oil tank storage room.
    • Gasförråd.
    • Computer data processing center.
    • IT software system room.
    • Telecommunication equipment room.
    • Art galleries.
    • Critical assets.
    • Original document storage.
    • Bank vault systems.
    • Wind power generator room.
    • Control panel room.
    • Elfördelningsrum.
    • The machinery storage facilities.
    • The sensitive devices storage facilities.
    • Marine, offshore, and Naval.
    • Cultural and historical sites.
    • Automated tape library.
    • Data center or storage room.
    • Circulates.
    • Hydraulic equipment and device.
    • Drying plant.
    • Deducting equipment room.
    • Natural gas station.
    • Refrigeration equipment.
    • Boiler factory.

    Inergen IG541 Fire Suppression System is a fully submerged fire extinguishing system that does not damage the environment and has excellent fire extinguishing effects for Class A, B, C, and E.

    Inert gas fire extinguishing systems are not only environmentally friendly, but also have low cost, so they are adopted in many engineering projects.

    The operation and installation method of this system is almost the same as that of HFC-227ea fire extinguishing systems, carbon dioxide fire extinguishing systems, etc., all of which belong to fire extinguishing systems that require the installation of pipeline networks.