Doen alles vir veiligheid,vir 'n veilige wêreld!

Minisol Fire Protection Device for Energy Storage System

» ons Blog » Minisol Fire Protection Device for Energy Storage System

Minisol Fire Protection Device for Energy Storage System

Maart 18, 2019

Why recommend Minisol fire protection device for contained energy storage system

In the new energy industry now there is a new thing appeared, we call a “vervat(behouerde) Stoor van energie”, so now a container is not only used to load cargo but also use for energy storage and energy saving.

vervat(behouerde) energy storage system is made up of an energy storage container, isolasie stelsel, ventilasiestelsel, elektriese stelsel, noodontruimingstelsel, brandbestrydingstelsel (fire protection device and fire alarm system), and dynamic loop monitoring system.

Inside the storage container room, all these relative electrical systems will require a good fire fighting system to be a fire protection system.

Every contained energy storage system has with super high cost, so it is necessary to install a suitable fire suppression system, en ons minisol aerosol fire protection device word aanbeveel.

OPMERKING: ESS is 'n afkorting vir Energy Storage Systems, en BESS is 'n afkorting vir Battery Energy Storage Systems, they include in-building, behouerde, en kabinetstelsels, 'n aerosol brandblusstelsel is welcome to be installed in battery room fire protection and is very highly effective.

Minisol brandblusstelsel Device vir vervat Energie Storage System

Know something about the Contained Energy Storage System First

In die eerste plek, Energiebergingshouer

Die energie stoor houer kamer is ontwerp om maklik te vervoer en maklik te installeer, inside has ventilation systems, isolasie stelsels, elektriese stelsels, brandbestrydingstelsels, noodontruimingstelsels, and dynamic loop monitoring systems, dit is met 'n streng en redelike ontwerpuitleg, die verbetering van die sekuriteit, ekonomiese doeltreffendheid, buigsaamheid van die werking.

It uses good quality steel as material, dit is goed geverf, anti-roes, en met luike in die hoek.

Normally a total flooding fire suppression system will have to be installed on the wall or the top ceiling of the container room, A gas fire extinguishing system, poeier brandonderdrukkingstelsel, water stelsel, and foam system all can be applied to installed in it, but as a simple and easy-to-install system, we recommend minisol aerosol and hanging type super-fyn droë chemiese poeier ABC.

For space-saving suggest installing minisol aerosol fire extinguishing system, and for economic and cost saving recommend the small size of hanging type super-fine ABC dry chemical powder.

Normaalweg is dit beter om die aërosolstelsel van Minisol te gebruik en in hierdie omgewing te installeer.

In die tweede plek, Termiese isolasiestelsel

A termiese isolasie stelsel is also designed and installed inside the ES container because inside the Energy storage container, there is many of electrical equipment over there and much thermal and heat are produced, so insulation plates and rock wool or polyurethane sandwich panels are always used as thermal insulation materials.

The thermal insulation system should be set on the top, at the bottom, and also on the wall.

ook, some air-conditioning system is used to control the room temperature.

Derdens, Ventilasiestelsel

The ventilation system is made up of an air passage, uitlaatwaaier, luginlaat, louver, and filter, Dit is die belangrikste funksie is ventilasie en hitte verspreiding.

This system is always the brother of fire fighting systems and thermal insulation systems, it works together with them to make sure the energy storage system operating well every day.

In die vierde plek, Elektriese Stelsel

The electrical system is die belangrikste stelsel in die ES-houer, including a lighting system, bedradingstelsel, grondstelsel, skakelstelsel, and energy power distribution system.

Lighting systems use waterproof, vog-proof, dust-proof lighting to extend its life span.

The wiring system should be set and convenient for maintenance and replacement.

The grounding system uses copper bars, to make electrical cabinets and boxes connect to the ground, om seker te maak van maklike installasie.

The power distribution system is with many electrical cabinets and control panels, en ook met baie ander elektriese elemente, these electrical elements and equipment are what we need to install a fire extinguishing system.

An emergency evacuation system is also necessary for an energy power storage system, including an emergency exit, ontruiming slot, nood beligting, and exit sign.

In die vyfde plek, Fire Fighting System (or fire protection device)

A fire fighting system is very necessary for every energy storage system, every energy storage container or electrical cabinet should set a completely good fire suppression system.

Want sonder 'n brandonderdrukkingstelsel, when the energy storage system causes a fire, dit sal ly aan 'n groot verlies. Never we should put people’s lives and assets in danger.

sesde, the Dynamic loop monitoring system

A dynamic loop monitoring system monitors the operating conditions in the container, Insluitend: temperatuur en humiditeit te monitor, opsporing en beheer van waterlekkasies, sekuriteitsmonitering, kragbeheer, and video monitoring.
By using this system we can monitor the running status in real-time, find the system problem at an earlier time, hint the maintenance staff to take necessary measurements to solve the problem, verbeter die gehalte van die onderhoud aansienlik, and improve the reliability and security of operation.

Design Minisol Aerosol Fire Protection Device for the Contained Energy Storage System

With all the above it is better to use a fire suppression system with the following characteristics:

  • As a 20-foot, 40-voet, and 45-foot container room is a very narrow space, better to use a small size of fire extinguishing device for a total flooding fire.
  • Daar is 'n paar klein elektriese kaste en beheerkaste binne in die houer, better to use a mini-size fire extinguishing device for local application purposes.
  • Aangesien die houerruimte beperk is, the fire extinguishing device should be easy to install.
  • ook, the fire extinguishing device must be environmentally friendly, nie-korrosiewe, waterdig, nie-geleidende, en onderhoudsvry.

Our Minisol brand of aerosol fire protection device has the above-described characteristics, and we strongly recommend it for installed energy storage systems.

Ons het baie gevalle in China om dit in hierdie area te installeer (mobiele energiestoorstelsel) in Brasilië, Chili, Europa, Singapoer, and Australia some overseas mobile energy storage power stations have already installed this kind of aerosol vuur onderdrukking toestel.

In Europa, Amerika, Japan, Korea, South America Area, etc every country and their government are striving to develop new energy and mobile energy storage systems.

Their requirement for new energy and mobile energy storage systems is increasing every year.

New energy power stations like solar power stations, wind power stations, nuclear power stations, and tidal power stations are advocated by the UN United States, Correspondingly energy power storage systems are also recommended and put into use soon.

There is a huge demand for installing our aerosol fire extinguishing systems in these container energy storage systems.

Aerosol brandblussing tegnologie is 'n nuwe brandbeskermings tegnologie in die wêreld, baie installeerders, engineers, and container producers do not know what is aerosol, how to use and how to install it, we are happy to share the newest aerosol fire suppression technology to whom may concern about it all over the world if any question about this special hazard fire suppression please feel free to let us knows.

thermo gloeilamp aerosol brandblusser kragopwekker 4

    Kyk meer na brandonderdrukkingsprodukte

    Miskien het jy wil ook