Doen alles vir veiligheid,vir 'n veilige wêreld!

Termiese Aerosol Generator Brandblusser vir Kabeltonnel

» produkte » Minisol -spuitblusser » Termiese Aerosol Generator Brandblusser vir Kabeltonnel
  • Termiese Aerosol Generator Brandblusser vir Kabeltonnel

    KATEGORIE en etikette:
    Minisol -spuitblusser, produkte

    A thermally activated aerosol generator fire extinguisher is a small, smart, and automatic fire extinguishing device, which can be applied in underground facilities such as utility cable tunnels, cable tench, and cable trays.

    ondersoek
    • spesifikasies
    • Benefits and Features
    • Application Examples
    • Meer inligting

    A thermal Cord is a sensitive self-combustible wire, dit is spontaan, when the environment temperature arrives at its rated activation temperature of 175℃ or 300℃, it will burn up and start the fire extinguisher.

    Cable tunnels are tunnels used for laying cables, which are more prone to fires, and following the requirements of the fire code, suitable fire extinguishing solutions need to be set up in cable tunnels.

    The thermal cord aerosol generator brandblusser can be applied in cable tunnels, kabelslote, and cable trays.

    The structure of cable tunnels is complex and the environment is harsh, so installing an aerosol fire extinguisher is a wise choice because of its special properties listed below:

    • It is the simplest fire-extinguishing system in the world at present.
    • It has waterproof and anti-corrosion functions, making it very suitable for cable tunnels.

    Thermal Aerosol Fire Extinguisher for Cable Well

    Parameters of Aerosol Fire Extinguisher 3000TH

    We can see its benefits for cable tunnels from the following parameters:

    • Unit Model: 3000TH, hiermee “TH” beteken termiese koord”.
    • The Diameter is 219 millimeter.
    • The Height is 295 millimeter.
    • Blusvolume: 30 kubieke meter.
    • Quality of Powdered Aerosol: 3000 gram.
    • Thermal Sensing Temperature: 175℃ en 300 ℃.
    • Canister Material: 304 Stainless Steel with artwork of polishing.
    • Totale gewig: 12500 gram.
    • Unit Weight: 3000 gram.
    • Ontslag Tyd: Minder as 40 sekondes.
    • operasie Temperatuur: minimum -40 ℃, maksimum +108℃.
    • Working Humiditeit: ≤95% nie-kondenserend.
    • ontwerp Digtheid: 100 gram per kubieke meter.
    • Canister Nozzle Temperature: ≤200 degrees Celsius.
    • Propellant Gas: Not have.
    • Operating Pressure: Geen.
    • Toxicity: Geen.

    It is usually installed on the top or side walls of cable tunnels, with a distance of 5 om 10 meters between devices.

    This product can be compatible with other systems inside cable tunnels, such as detection systems, alarm systems, power systems, ens.

    Many people cannot understand why aerosol fire extinguishing devices can be installed in cable facilities. Please refer to Aerosol Fire Extinguishing Generators Apply In Cable Trench.

    We carefully counted and found that our product has the following benefits and features:

    • Fast speed to extinguish the fire.
    • Effektiewe en hoë werkverrigting, with aerosol powder concentration of 100g/m3.
    • Nie elektries geleidend nie.
    • Minimaliseer skade.
    • Harmless to the human body and animals.
    • Simple to integrate with fire alarm systems.
    • Easy to install and maintenance-free.
    • Clean aerosol powder halon alternative.
    • No ozone depletion, and no global warming.
    • Nie-giftige.
    • Piping is not required.
    • Vir Klas A, B, C, E, and F total flooding applications.
    • Extremely cost-effective.

    This product not only be applied in cable tunnels, kabelslote, and cable trays but also has a wider application, verwys asseblief na die volgende:

    • Telekommunikasie fasiliteite.
    • Datasentrums.
    • Rekenaar numeriese beheer masjien.
    • Marine enjin kompartement.
    • Windturbines.
    • Pakhuise en stoorkamers.
    • Voertuig enjins.
    • Elektriese panele.
    • Stoor vlambare vloeistof.
    • Generator and compressor rooms and compartments.
    • Vlambare en brandbare vloeistowwe.
    • Paint rooms.
    • Battery storage rooms.
    • stoor gas kamer.

    When handling an aerosol fire extinguisher, please note the following important points:

    • Do not disassemble the condensing aerosol generator privately to prevent accidents.
    • Do not deform the product housing.
    • Do not carry out welding or other flammable work in the vicinity of aerosol fire extinguishers.
    • Do not smoke near aerosol fire extinguishers.
    • If an aerosol fire extinguishing device is dropped on the ground during handling or installation, make sure that its ignition device and electrical circuitry are intact.
    • This product is dangerous goods, it should be well protected in the transport process.

    Enquiry Form ( ons sal terug te kry wat jy so gou as moontlik )

    naam:
    *
    e-pos:
    *
    Boodskap:

    Verifikasie:
    0 + 4 = ?

    Miskien het jy wil ook