Basic Description
Factory space is with cargo and has workers working over there, and with kinds of machines running every day over there, so it seems not very suitable to put a fire extinguishing device on the floor, some gas fire extinguishing systems are also not very appropriate to install in factory because the factory is normally not a confined space. Instead, a ceiling-mount dry chemical suppression device is a good solution for a food factory.
We need a fire extinguishing device to install in the factory which has the functions of:
- 1. Can be installed on the ceiling or the wall.
- 2. Rapidly Extinguishing the fire.
- 3. Can be applied as a local application, direct-to-source, and total flooding.
- 4. Can suppress fire in open areas.
Furthermore, many other factories like garment factories, cement factories, chemical factories, furniture factories, and many others also need fire extinguishing devices with similar functions above described.
So we recommend our ABC Dry Chemical Powder Fire Suppression System ceiling mount fire suppression device for factories including food factories, and beverage factories.
Model Numbers of the Ceiling-Mount Dry Chemical Suppression Device
Model Numbers with below available:
FZX-ACT1 (pressure 1.2 MPA) COVERING 8.3 Cubic meters or 4.2 square meters.
FZX-ACT2 (pressure 1.2 MPA) COVERING 16.67 Cubic meters or 8.3 square meters.
FZX-ACT3 (pressure 1.2 MPA) COVERING 25 Cubic meters or 12.5 square meters.
FZX-ACT4 (pressure 1.2 MPA) COVERING 33.33 Cubic meters or 16.6 square meters.
FZX-ACT5 (pressure 1.2 MPA)COVERING 41.67 Cubic meters or 20.8 square meters.
FZX-ACT6 (pressure 1.2 MPA) COVERING 50 Cubic meters or 25 square meters.
FZX-ACT7 (pressure 1.2 MPA) COVERING 58.33 Cubic meters or 29.2 square meters.
FZX-ACT8 (pressure 1.2 MPA) COVERING 66.67 Cubic meters or 33.3 square meters.
FZX-ACT9 (pressure 1.2 MPA) COVERING 75 Cubic meters or 38 square meters.
FZX-ACT10 (pressure 1.2 MPA) COVERING 83.33 Cubic meters or 41.7 square meters.
A food factory always has some open area, so it is not suitable to install gas and aerosol fire suppression systems, but able to install dry chemical, foam, and water systems, furthermore, as foam and water systems are always will destroy food in the workshop, so it seems the dry chemical system to be the best solution for food factory fire protection.
We have many installation cases for this product installed in food factories in China and overseas markets, Except for China, we have many installation jobs in other countries, there are:
- In Myanmar.
- In the Philippines.
- In Indonesia.
- In South Africa.
- In Chile.
- In Brazil.
- In Kuwait.
- In Dubai.
- In Sri-Lanka.
- In Korea.
- In Mexico.
- In Vietnam.