Kategorien
- Unser Blog (71)
- Technology Support (18)
Many customers after having a look at our condensed aerosol fire suppression system, showed a lot of interest, but they did even not know how to choose our different models and types because for aerosol products we have three basic series, es gibt: Boden stehende Serie, Wandserien und Minisol-Serien.
The standing series is square and could be red color painted or silver-white color painted, Ihre Größe beträgt normalerweise 400 * 300 * 680 mm und 600 * 300 * 680 mm, or another special design size, mit 2.5 Kilogramm zu 10 Kilogramm Aerosol-Löschmittel-Füllung innen, die wichtigsten modelle sind wie folgt:
. AW-QRR2.5LW/S.
. AW-QRR5LW / S.
. AW-QRR7.5LW/S.
. AW-QRR10LW/S.
Wie wir sehen können, it just needs to be put in the ground to install, it is large and filled with a large quality aerosol compound in kilograms, so it is suitable to install in some spaces with a volume of more than several tens of cubic meters or for some large projects, and also there must be some leftover space to put the device on corner of the ground, sowie:
. Computerräume.
. Telekommunikationsräume.
. Datenverarbeitungsräume.
. Umspannwerke.
. Kabelgewölbe, Kabelgraben, and cable well.
. National Library.
. Museen.
. Archiv.
. The large size of low and high-voltage power distribution rooms.
. Große Stromerzeugerräume etc.
It is recommended to install it in a bigger space because it is more economical in pricing, Vor allem der Stromverteilerraum, Computerraum, Bibliothek, Museum, etc are more suitable to use this style.
Wall mounted series is cylindrical and could be red color painted or silver white color painted, Ihre Größe beträgt normalerweise Durchmesser 300 * 700 mm oder Durchmesser 300 * 800 mm, or other special design sizes, mit 2.5 Kilogramm zu 10 Kilogramm Aerosol-Löschmittel-Füllung innen, die wichtigsten modelle sind wie folgt:
. AW-QRR5GW/S.
. AW-QRR7.5GW/S.
. AW-QRR10GW / S..
Wie wir sehen können, it needs to be installed on the wall or the top ceiling, es hat die mittlere Größe und die Qualität der großen Aerosolverbindung in Kilogramm, it is also suitable for installation in some spaces with a volume of more than several tens of cubic meters or a large project, it better to install in the site that requires to install on the wall or the ceiling, sowie:
. Computerraum.
. Telekommunikation Zimmer.
. Transformatorraum.
. U-Rohr-Galerie.
. Stromverteilungsraum.
. Stromerzeugungsraum.
. Datenverarbeitungsraum etc.
It is recommended to install in the median size of space and install where there is little space left on the ground to put a fire extinguishing device because it is more economical in pricing and space-saving by installing it on the ceiling or the wall.
Especially the underground pipe gallery and wind power energy industry are better to use this kind of.
Minisol Aerosol der festen Serie is also in cylindrical size, es ist 304 stainless cylinders in silver white color (Edelstahlfarbe), die größe ist sehr klein oder kleiner, the minimum size is the diameter of 51*95mm and the maximum size is the diameter of 219*295mm, mit 0.03 Kilogramm zu 3 Kilogramm Aerosol-Löschmittel-Füllung innen, die wichtigsten modelle sind wie folgt:
. AW-QRR0.03GW / S (30 Gramm).
. AW-QRR0.06GW / S (60 Gramm).
. AW-QRR0,1GW / S (100 Gramm).
. AW-QRR0,15GW / S (150 Gramm).
. AW-QRR0,2GW / S (200 Gramm).
. AW-QRR0,25GW/S (250 Gramm).
. AW-ARR0.3GW/S (300 Gramm).
. AW-QRR0.5GW/S (500 Gramm).
. AW-QRR0.75GW/S (750 Gramm).
. AW-QRR1GW / S (1000 Gramm).
. AW-QRR1.5GW/S (1500 Gramm).
. AW-QRR2GW / S (2000 Gramm).
. AW-QRR2.5GW/S (2500 Gramm).
. AW-QRR3GW / S (3000 Gramm).
weil:
Da es vielseitig ist, flexible, und klein, people can install it everywhere inside and outside the protection room (Schutzobjekt), sowie:
. Telekommunikationsräume.
. Power transformer rooms.
. Distributing rooms.
. Power-generating rooms.
. Datenverarbeitungsräume.
. Platz im Schaltschrank.
. Elektrischer Schaltkasten und Platine.
. Vehicle auto engine compartments, wie Busse, Autos, Trainer, und LKWs.
. Windkraft-Energiefach.
. CNC-Maschinen, printing machines, Geldautomaten, und so weiter.
For some projects it is very complicated, not only does the room need to be protected but also the electrical cabinet or machines need to be protected as well, in this condition both Floor standing Aerosol (or wall-mounted aerosol) and mini fixed aerosol fire extinguishing devices are required to install.
Beispielsweise, a computer server room is 20 Meter lang, 15 meters in width, und 4 Meter hoch, es gibt 60 sets of cabinets inside the room and their size are 60 Zentimeter lang, 50 centimeters in width, und 2 Meter hoch, we are planning to design aerosol fire extinguishing device as a fire solution, then we install wall-mounting or floor standing aerosol for the whole room and the Minisol aerosol fire extinguisher for the cabinet, Designdetails wie unten:
okay, wenn Leute unsere Aerosolprodukte für ihr laufendes Projekt installieren, sie werden immer fragen: “Do you also have a fire alarm system?”, “How can we connect a fire alarm system with your products?”, “do we need to design a fire alarm system together with your aerosol products?” etc.
For these questions, our answer is “Ja”, we can provide fire alarm systems as per clients’ Bedarf, but how to design and connect a fire alarm system with our aerosol systems is divided into 2 parts:
Siehe unten stehende Artikel:
Lithium-Batterie-Brandschutz-Mini-Aerosolsystem für New Energy Vehicles
Automatische Sprühdosenlöscheinrichtung für elektrische Gehäuse und Gehäuse
Aerosol fire extinguisher and suppression system for bank GeldautomatAerosol-Brandschutzsystem für besondere Gefahren für kritische Anwendungen
In these articles, there are many installation photos you can see, that all the installed mini aerosol devices work standalone without any power supply and without connecting and designing with fire alarm systems together. (Anmerkung: in some vehicle engine rooms if customers have special requirements for installing fire alarm systems, wir können sie auch verwenden, for this issue if there is any doubt please contact us for a further discussion).
Some people will say “I just want to have a fire detection to work with your aerosol device, Wie können wir diese Funktion erfüllen fulfill?”, okay this is easy we have a special fire detection product called “Wärmeaktivierungs Generator”, and it can detect out fire at its rated temperature 45℃, 70℃, 93℃, 110℃ after detecting out a fire it can activate the Minisol aerosol automatically by sending out a small current, Das sind die Produktlinks:
https://www.awarefire.com/stand-alone-system-thermal-activation-generator/
And here is an article to tell you how it connects with aerosol:
Can we make the aerosol fire extinguisher work standalone without any outer power supply
See from the above description we can see that aerosol fire extinguishing systems now is widely used in many industries and have a great marketing prospect all over the world, floor standing aerosol and wall-mounted aerosol are mainly for some projects, and Minisol fixed aerosol is for some small project or some particular special hazard fire protection.
okay, this article is to tell you about aerosol installation in different places.
If you like this but don’t know how to do it, then contact us we will communicate with you and offer help.
Bezug:
Hereby are some international standards/regulations/rules for aerosol fire extinguishing systems:
Standard für Feuerlöschsysteme mit festem Aerosol: NFPA 2010
Feuerlöschsysteme mit kondensierten Aerosolen – Anforderungen und Prüfmethoden für Komponenten- und Systemdesign, Installation, and maintenance – Allgemeine Anforderungen