Sind alle für die Sicherheit,für eine sichere Welt!

Trockenpulverlöscher für Oil Depot

» Produkte » Trockenchemische Feuerlöschsysteme » Dry powder extinguisher for Oil Depot
  • Trockenpulverlöscher für Oil Depot

    KATEGORIE UND TAGS:
    Trockenchemische Feuerlöschsysteme

    The stress-free ultrafine ABC dry powder extinguisher is a device that quickly suppresses fire. Its fire-extinguishing particles are fine and white, and it can effectively extinguish fires of types A, B, C, E, und F.

    Anfrage
    • Technische Daten
    • Charakteristisch
    • Other Application Areas
    • Weitere Angelegenheiten

    Why are dry powder extinguisher systems suitable for oil depot fire protection? Let’s start with an introduction to oil depots first.

    An oil depot is a specialized facility designed to store oil. It is a crucial link in coordinating the production of crude oil, processing crude oil, supply of refined oil, and transportation. It also serves as the foundation for the national oil reserve and supply, which is of great importance in safeguarding national defense and promoting the high-speed development of the national economy.

    Each country has its own set of regulations for fire safety in oil depots. For instance, storing dangerous goods, explosives, and other flammable materials is strictly prohibited. Infolge, fire protection in oil depots is subject to stringent measures. Deswegen, selecting an appropriate fire extinguishing system is of utmost importance.

    Based on practice, people have found that several fire extinguishing systems are very suitable for oil depot fire protection, Eines davon ist das Impuls-Trockenpulver-Feuerlöschsystem, Das ist stressfrei.

    Technical Data of The Dry Powder Extinguisher

    This dry powder extinguisher has ultra-fine fire extinguishing particles, which makes the fire extinguishing agent spray more evenly.

    In der folgenden Listentabelle, let’s list the parameters or data sheet of this impulse-type ultrafine dry powder extinguisher:

    • Produktbeschreibung: Stress-free impulse ultrafine dry chemical powder
    • Funktion: Suppressing fire.
    • Produktmodell: FFX-ACT(ACF)3, FFX-ACT(ACF)5, FFX-ACT(ACF8), FFX-ACT(ACF)10.
    • Filling Quality of Ultrafine ABC Dry Chemical Powder: 3 nach 10 Kilogramm Unterschied.
    • Total Flooding Protection Volume: Ranges from 20 nach 77 Kubikmeter.
    • Standard Design Density: 128 nach 130 Gramm pro Kubikmeter.
    • Installation Temperature Range: -40℃ bis +50℃.
    • Zeitpunkt der Freigabe: Aus 5 nach 10 Sekunden.
    • Spray Residual rate: ≤5%.
    • Voltage for Operation: 3 nach 24 Volt.
    • Einschaltstrom: Mehr als 0.45 EIN.
    • Safe Aktuelle: Weniger als 0.15 EIN.
    • Extinguishing Forms: insgesamt Flooding, Local Application, and Direct-to-Source.
    • Produktlebensdauer: 6 nach 10 Jahre.
    • Garantiezeit: 24 Monate bzw 2 Jahre.

    Für mehr Details, Bitte fragen Sie uns danach Installationsanleitung.

    More models ranging from 3 Kilogramm zu 10 kilograms are available.

    Dry Powder Extinguisher Device

    Why can ultrafine dry powder fire extinguishing devices be used for oil depot fire extinguishing? because they have the following characteristics:

    • They are extremely fast fire extinguishers, capable of spraying agents instantly and extinguishing a fire in about 1 Sekunde nach der Aktivierung.
    • The fire extinguishing agent is composed of fine particles, which are evenly distributed after spraying, resulting in high fire extinguishing efficiency, Umweltschutz, and no pollution.
    • Lagerung bei Atmosphärendruck, and require no maintenance.
    • They cover the surface of the flame well, extinguish open flames, and are not easily dispersed by the wind.
    • They separate the oil and air, preventing the fire from burning.
    • Multiple fire extinguishing modes are available, such as total flooding and local application extinguishing modes.
    • The only downside is the loud noise during spraying.
    • They can be used in open areas, including outdoor electric vehicle parking shelters.

    Except for the oil depot, this product can be widely installed in some other places and sites:

    • national Convention Center.
    • Sports stadium.
    • Steel works.
    • Nuclear power plant, hydroelectric power plant, photovoltaic power plant.
    • Public Health Management Center.
    • Lighting station.
    • Sewage treatment station.
    • Transformer Power Station.
    • Fertigungswerkstatt.
    • Grain and oil warehouse.
    • Urban underground comprehensive pipe gallery and cable tunnel.
    • Hafenterminal.
    • Flughafenhangar.
    • Garage.
    • Armament Depot.
    • Underground Parking.
    • Heizungsraum.
    • Natural gas pressure stations and injection stations.

    aber, it is not applicable in the following places:

    • The crowded place.
    • Places for precision instruments or equipment.
    • Places where nitrocellulose can rapidly oxidize chemicals and strong oxidants without air.

    Please take note of the following important points:

    • Only a professional should handle the disassembly of the fire extinguishing device with proper authorization to avoid any personal injury.
    • It is not advisable to install this device in high-traffic areas such as airports, Bahnhöfe, Bushaltestelle, etc.
    • The installation temperature should be between -40 und 50 Grad. Please store the device in a well-ventilated and dry place during storage.
    • Before installing the fire extinguishing device, carefully read the installation manual and verify the list to ensure proper installation.