Why recommend Minisol fire protection device for contained energy storage system

In the new energy industry now there is a new thing appeared, we call a “Enthalten(containerisiert) Energiespeichersystem”, so now a container is not only used to load cargo but also use for energy storage and energy saving.

Enthalten(Containerisiert) energy storage system is made up of an energy storage container, Isoliersystem, Belüftungssystem, elektrisches System, Notfall-Evakuierungssystem, Feuerlöschanlage (fire protection device and fire alarm system), and dynamic loop monitoring system.

Inside the storage container room, all these relative electrical systems will require a good fire fighting system to be a fire protection system.

Every contained energy storage system has with super high cost, so it is necessary to install a suitable fire suppression system, und unser minisol aerosol fire protection device ist empfohlen.

ANMERKUNG: ESS steht für Energy Storage Systems, und BESS steht für Battery Energy Storage Systems, they include in-building, containerisiert, und Schranksysteme, Ein Aerosol-Feuerlöschsystem is welcome to be installed in battery room fire protection and is very highly effective.

Minisol Feuerlöschgerät für enthaltenes Energiespeichersystem

Know something about the Contained Energy Storage System First

Erstens, Energiespeicherbehälter

Das Behälter zur Energiespeicherung Zimmer ist leicht zu transportieren und einfach zu installieren, inside has ventilation systems, Dämmsysteme, elektrische Systeme, Feuerlöschsysteme, Notfall-Evakuierungssysteme, and dynamic loop monitoring systems, es ist mit einem strengen und vernünftigen Design-Layout, Verbesserung der Sicherheit, Wirtschaftlichkeit, Flexibilität im Betrieb.

It uses good quality steel as material, es ist gut bemalt, Korrosionsschutz, und mit Fensterläden in der Ecke.

Normally a total flooding fire suppression system will have to be installed on the wall or the top ceiling of the container room, A gas fire extinguishing system, Pulverlöschanlage, Wassersystem, and foam system all can be applied to installed in it, but as a simple and easy-to-install system, we recommend minisol aerosol and hanging type superfeines ABC-Trockenchemikalienpulver.

For space-saving suggest installing minisol aerosol fire extinguishing system, and for economic and cost saving recommend the small size of hanging type super-fine ABC dry chemical powder.

Normalerweise ist das Minisol-Aerosolsystem besser in diesem Bereich anzuwenden und zu installieren.

Zweitens, Wärmedämmsystem

EIN Wärmedämmsystem is also designed and installed inside the ES container because inside the Energy storage container, there is many of electrical equipment over there and much thermal and heat are produced, so insulation plates and rock wool or polyurethane sandwich panels are always used as thermal insulation materials.

The thermal insulation system should be set on the top, at the bottom, and also on the wall.

Ebenfalls, some air-conditioning system is used to control the room temperature.

Drittens, Belüftungssystem

The ventilation system is made up of an air passage, Abluftventilator, Lufteinlass, Jalousie, and filter, seine Hauptfunktion ist Belüftung und Wärmeableitung.

This system is always the brother of fire fighting systems and thermal insulation systems, it works together with them to make sure the energy storage system operating well every day.

Viertens, Elektrisches System

The electrical system ist das wichtigste System im ES-Container, including a lighting system, Verdrahtungssystem, Erdungssystem, Schaltsystem, and energy power distribution system.

Lighting systems use waterproof, feuchtigkeitsbeständig, dust-proof lighting to extend its life span.

The wiring system should be set and convenient for maintenance and replacement.

The grounding system uses copper bars, to make electrical cabinets and boxes connect to the ground, um eine einfache Installation zu gewährleisten.

The power distribution system is with many electrical cabinets and control panels, und auch mit vielen anderen elektrischen Elementen, these electrical elements and equipment are what we need to install a fire extinguishing system.

An emergency evacuation system is also necessary for an energy power storage system, including an emergency exit, Evakuierungsschleuse, Notfallbeleuchtung, and exit sign.

Fünftens, Fire Fighting System (or fire protection device)

A fire fighting system is very necessary for every energy storage system, every energy storage container or electrical cabinet should set a completely good fire suppression system.

Denn ohne Feuerlöschanlage, when the energy storage system causes a fire, es wird einen großen Verlust erleiden. Never we should put people’s lives and assets in danger.

Sechste, the Dynamic loop monitoring system

A dynamic loop monitoring system monitors the operating conditions in the container, einschließlich: Überwachung von Temperatur und Luftfeuchtigkeit, Erkennung und Kontrolle von Wasserlecks, Sicherheitsüberwachung, Stromschalter, and video monitoring.
By using this system we can monitor the running status in real-time, find the system problem at an earlier time, hint the maintenance staff to take necessary measurements to solve the problem, die Qualität der Wartung deutlich verbessern, and improve the reliability and security of operation.

Design Minisol Aerosol Fire Protection Device for the Contained Energy Storage System

With all the above it is better to use a fire suppression system with the following characteristics:

  • As a 20-foot, 40-Fuß, and 45-foot container room is a very narrow space, better to use a small size of fire extinguishing device for a total flooding fire.
  • Wie im Inneren des Containers sind einige kleine Schaltschränke und Schaltkästen eingebaut, better to use a mini-size fire extinguishing device for local application purposes.
  • Da der Containerraum begrenzt ist, the fire extinguishing device should be easy to install.
  • Ebenfalls, the fire extinguishing device must be environmentally friendly, nicht korrosiv, wasserdicht, nicht leitend, und wartungsfrei.

Our Minisol brand of aerosol fire protection device has the above-described characteristics, and we strongly recommend it for installed energy storage systems.

We have many cases in China to install it in this area (mobiler Energiespeicher) in Brasilien, Chile, Europa, Singapur, and Australia some overseas mobile energy storage power stations have already installed this kind of Aerosol-Brandunterdrückungsvorrichtung.

In Europa, Amerika, Japan, Korea, South America Area, etc every country and their government are striving to develop new energy and mobile energy storage systems.

Their requirement for new energy and mobile energy storage systems is increasing every year.

New energy power stations like solar power stations, wind power stations, nuclear power stations, and tidal power stations are advocated by the UN United States, Correspondingly energy power storage systems are also recommended and put into use soon.

There is a huge demand for installing our aerosol fire extinguishing systems in these container energy storage systems.

Aerosol-Feuerlöschtechnik ist eine neue Brandschutztechnologie der Welt, viele Installateure, engineers, and container producers do not know what is aerosol, how to use and how to install it, we are happy to share the newest aerosol fire suppression technology to whom may concern about it all over the world if any question about this special hazard fire suppression please feel free to let us knows.

Thermo-Lampen-Aerosol-Feuerlöscher-Generator 4

    Weitere Produkte zur Brandbekämpfung anzeigen

    Vielleicht gefällt Ihnen auch