Do all for safety,for a safe world!

Aerosol Fire Prevention Systems for Power Generator Room

» Products » Minisol Aerosol Fire Extinguisher » Aerosol Fire Prevention Systems for Power Generator Room
  • Aerosol Fire Prevention Systems for Power Generator Room

    CATEGORY AND TAGS:
    Minisol Aerosol Fire Extinguisher, Products

    This is a non-toxic, non-conductive, and environmentally friendly aerosol fire extinguisher generator, we strongly recommend it to be installed in autobus engine compartments.
    To make every bus and car safe.

    enquiry
    • Specifications
    • Own Features
    • Application
    • More Notes

    “Do aerosol fire prevention systems for power generator room?”, Some partners ask this question.

    Our answer is “yes” because the power generator room is usually an enclosed space and aerosol devices are specifically designed for use in total flooded enclosed space fires.

    The generator room is an important place for power supply, where there are a large number of power supply equipment. If a fire occurs, the losses will be very large.

    Power Generator Room Aerosol Fire Prevention System

    Basic Data of Aerosol Fire Prevention Systems

    So if we can install aerosol fire prevention systems in this room, then we will not worry about fires, below are the basic data and parameters of an aerosol fire extinguisher with 500 gram capacity:

    • Generic Name: Aerosol-based fire prevention systems.
    • Style: 500E.
    • Extinguishing Volume: 5 m³.
    • Mass of Aerosol Powder: 500 grams.
    • Design Concentration: 100 grams per cubic meter.
    • Specification of the Product: 126*126*184 millimeters, or as the customer’s design size.
    • Launch Mode: electrical power supply with DC 3 to 24 volts, AC 3 to 220 volts.
    • Cylinder Material: 304 stainless steel.
    • The Colour of the Aerosol Agent: is brown.
    • Main Oxidants of Aerosol Powder: strontium nitrate and potassium nitrate.
    • Weight of the Device: 3500 grams.
    • Outgassing Time: no more than 30 seconds.
    • Service Time: 10 years.
    • Fire Extinguishing Rating: Class A, B, C, E, F.

    Item 500E aerosol extinguisher is an electrical activation mode suppression device, This fire extinguisher can be activated with a voltage input of 3 to 24 volts.

    Of course, for safety reasons, we can also choose a dual-start aerosol fire extinguisher, model number AW-QH-500E/TH.

    The advantage of dual-start aerosol fire extinguishers is that there are two guarantees in the starting method:

    • Electricity Start-up.
    • Thermal sensitive wires(thermal cord) Start-up.

    automatic fire extinguishing systems for substation electrical power distribution room switch transformer

    There may be some small cabinets in the generator room, and we recommend installing our mini fire extinguishers for these small cabinets- a small-capacity fire extinguisher.

    mini aerosol fire extinguishing system

    Compared with other piping extinguishing systems, this aerosol fire prevention system has the following features and advantages:

    • Not having any pressure to work, the aerosol agent is without cylinder pressure, so it is safe for transportation, in which some gaseous fire suppression system has pressure and are not safe.
    • Easy to do the installation job, because it does not have a pipeline network.
    • High concentration and high fire extinguishing efficiency.
    • Low in maintenance, because it does not require yearly inspection and non-pipeline.
    • It does not have pollution to the environment, its ozone layer depletion value is zero, global warming potential value is zero.

    It is widely applied in many industries and fields:

    • Power generator plant and its room.
    • Transformer stations.
    • Substation base and its room.
    • Hotels and restaurants.
    • Aviation airplanes.
    • Auto vehicles.
    • Renewable energy storage.
    • Supermarket and high-rise buildings.
    • Library, museum, and archives.
    • Underground pipeline network.
    • Electrical room.
    • Power station.
    • Standby generator.
    • Diesel generator.
    • Genset.
    • Engine room.
    • Turbine hall.
    • Battery room.
    • Power management system.
    • Mechanical room.
    • Emergency power system.
    • Railway base station etc.

     

    "Are aerosol fire extinguishers effective?", some people like to ask this question.

    We have to say that for confined space it is very effective because it is designed density is 100 grams per cubic meter, which means a 1000-gram aerosol compound will be able to cover a 10 cubic meters space room.

    In some European companies, their aerosol design density could be 50 to 100 grams per cubic meter, much more effective, but they are not as eco-friendly as our products.

    Enquiry Form ( we will get back you as soon as possible )

    Name:
    *
    Email:
    *
    Message:

    Verification:
    2 + 9 = ?

    Maybe you like also