Tehke kõik turvalisuse nimel,turvalise maailma eest!

Termoaerosoolgeneraatori tulekustuti kaabeltunneli jaoks

» Tooted » Minisol aerosool tulekustuti » Termoaerosoolgeneraatoriga tulekustuti kaabeltunneli jaoks
  • Termoaerosoolgeneraatori tulekustuti kaabeltunneli jaoks

    KATEGOORIA JA MÄRGID:
    Minisol aerosool tulekustuti, Tooted

    A thermally activated aerosol generator fire extinguisher is a small, tark, and automatic fire extinguishing device, which can be applied in underground facilities such as utility cable tunnels, cable tench, and cable trays.

    päring
    • Tehnilised andmed
    • Benefits and Features
    • Application Examples
    • Rohkem informatsiooni

    A thermal Cord is a sensitive self-combustible wire, see on spontaanne, when the environment temperature arrives at its rated activation temperature of 175℃ or 300℃, it will burn up and start the fire extinguisher.

    Cable tunnels are tunnels used for laying cables, which are more prone to fires, and following the requirements of the fire code, suitable fire extinguishing solutions need to be set up in cable tunnels.

    The thermal cord aerosoolgeneraatoriga tulekustuti can be applied in cable tunnels, kaablikraavid, and cable trays.

    The structure of cable tunnels is complex and the environment is harsh, so installing an aerosol fire extinguisher is a wise choice because of its special properties listed below:

    • It is the simplest fire-extinguishing system in the world at present.
    • It has waterproof and anti-corrosion functions, making it very suitable for cable tunnels.

    Thermal Aerosol Fire Extinguisher for Cable Well

    Parameters of Aerosol Fire Extinguisher 3000TH

    We can see its benefits for cable tunnels from the following parameters:

    • Unit Model: 3000TH, käesolevaga “TH” tähendab termilist juhet”.
    • The Diameter is 219 millimeetrit.
    • The Height is 295 millimeetrit.
    • Kustutusmaht: 30 kuupmeetrit.
    • Quality of Powdered Aerosol: 3000 grammi.
    • Thermal Sensing Temperature: 175℃ ja 300 ℃.
    • Canister Material: 304 Stainless Steel with artwork of polishing.
    • Brutokaal: 12500 grammi.
    • Unit Weight: 3000 grammi.
    • Tühjenemise aeg: Vähem kui 40 sekundit.
    • Töötemperatuur: minimaalselt -40 ℃, maksimaalne +108 ℃.
    • Töötav niiskus: ≤95% mittekondenseeruv.
    • Kavandatud tihedus: 100 grammi kuupmeetri kohta.
    • Canister Nozzle Temperature: ≤200 kraadi Celsiuse järgi.
    • Propellant Gas: Not have.
    • Operating Pressure: Mitte ühtegi.
    • Toxicity: Mitte ühtegi.

    It is usually installed on the top or side walls of cable tunnels, with a distance of 5 juurde 10 meters between devices.

    This product can be compatible with other systems inside cable tunnels, such as detection systems, alarm systems, power systems, jne.

    Many people cannot understand why aerosol fire extinguishing devices can be installed in cable facilities. Please refer to Kaablikraavis töötavad aerosoolide tulekustutusgeneraatorid.

    We carefully counted and found that our product has the following benefits and features:

    • Fast speed to extinguish the fire.
    • Tõhus ja kõrge jõudlus, with aerosol powder concentration of 100g/m3.
    • Ei ole elektrit juhtiv.
    • Minimeerige kahju.
    • Harmless to the human body and animals.
    • Simple to integrate with fire alarm systems.
    • Easy to install and maintenance-free.
    • Clean aerosol powder halon alternative.
    • No ozone depletion, and no global warming.
    • Mittetoksiline.
    • Piping is not required.
    • A-klassi jaoks, B, C, E, and F total flooding applications.
    • Extremely cost-effective.

    This product not only be applied in cable tunnels, kaablikraavid, and cable trays but also has a wider application, palun vaadake järgmist:

    • Telekommunikatsioonirajatised.
    • Andmekeskused.
    • Arvuti arvjuhtimismasin.
    • Laeva mootoriruum.
    • Tuuleturbiinid.
    • Laod ja laoruumid.
    • Sõidukite mootorid.
    • Elektripaneelid.
    • Tuleohtlike vedelike hoiustamine.
    • Generator and compressor rooms and compartments.
    • Tuleohtlikud ja põlevad vedelikud.
    • Paint rooms.
    • Battery storage rooms.
    • Gaasi hoiuruum.

    When handling an aerosol fire extinguisher, please note the following important points:

    • Do not disassemble the condensing aerosol generator privately to prevent accidents.
    • Do not deform the product housing.
    • Do not carry out welding or other flammable work in the vicinity of aerosol fire extinguishers.
    • Do not smoke near aerosol fire extinguishers.
    • If an aerosol fire extinguishing device is dropped on the ground during handling or installation, make sure that its ignition device and electrical circuitry are intact.
    • This product is dangerous goods, it should be well protected in the transport process.

    Päringuvorm ( võtame teiega esimesel võimalusel tagasi )

    Nimi:
    *
    Meil:
    *
    Sõnum:

    Kontrollimine:
    4 + 9 = ?

    Võib-olla meeldib teile ka