Fire Detecting Tube Device est reconnu comme un nouveau dispositif d'extinction d'incendie, il est largement utilisé dans les projets d'ingénierie pratiques et devient de plus en plus populaire.
Donc par rapport aux autres systèmes d'extinction d'incendie conventionnels, what are the advantages of fire detection tube devices? And how to choose a fire detection tube to install in practical engineering?
Fire Detection tubes have their unique advantages, and are widely applied in electrical cabinets, tunnels de câbles, puits de câble, and some other smaller spaces, people in the social are pay more attention to this product, and it has become remembered and recommended by more and more people.
In the worldwide market now 3 styles of fire extinguishing agents can be applied in tube fire systems, il y a:
In the Chinese market, maintenant, we mainly use carbon dioxide and HFC-227ea, and in the European and American markets now there is also NOVEC 1230.
This device is made up of a storage cylinder, le tube siphon, soupape de récipient, tuyau de détection d'incendie, and pressure gauge, lorsque nous installons cet appareil dans un espace de protection selon une certaine distance, quand le feu commence, le tube de détection d'incendie à proximité de la flamme de la chaleur se capteur, et dont l'emplacement pour atteindre le point de fusion va obtenir le dynamitage, l'agent d'extinction d'incendie exécuté par l'intermédiaire de la sortie ou buse, puis inondation totale des dangers pour éteindre le feu.
Pour vous montrer pourquoi l'appareil est de plus en plus populaire, below is a comparison chart between fire detection tube devices with other conventional fire suppression systems, voir dans le tableau ci-dessous, vous verrez leur différence, avantages, and features:
Comparaison article | Système d'extinction d'incendie classique | Système de dispositif de détection d'incendie Tube |
objet de protection | Grand espace fermé comme objet de protection incendie, take the whole room as protection zone, ne pas être en mesure d'installer à l'intérieur de l'équipement. | There is a small space or cabinet in the large enclosed space and, par exemple, a distribution cabinet, or communication cabinet, à l'intérieur du dispositif. |
Construction et installation | 1. Complexe dans la construction, et longue période de construction, besoin d'espace de cylindre spécial; 2. Besoin d'un détecteur de fumée et un détecteur de chaleur; 3. Ne pas être en mesure d'atteindre petit espace pour la protection incendie; 4. tuyaux complexes à installer. | 1. Facile à installer, et courte période de construction, pas besoin d'une salle de cylindre; 2. Ne pas besoin détecteur de fumée et un détecteur de chaleur; 3. Peut-être en mesure d'atteindre petit espace pour la protection incendie; 4. Facile à installer. |
Entretien et exploitation | 1. Besoin d'alimentation d'incendie spécial; 2. As it has electronic components, easy to get false alarms because of oil, poussière, and electromagnetic interference; 3. Electronics components will easy to lose operational function because of vibration and crash; 4. The System is a bit complex and needs a professional technician to do maintenance. | 1. Do not need a power supply; 2. A fire detection tube is a non-mental tube, that will not be able to affected by oil, poussière, or electromagnetic interference, not easy to get false alarms; 3. Not have electronic components; 4. The System is easy to do maintenance. |
Performances de sécurités | Design for total flooding of the fire protection room, utiliser beaucoup d'agent extincteur pour supprimer, quand travaille les gens doivent quitter | Conception d'inondation totale du feu pour les objets de protection, moins agent extincteur pour supprimer, quand les gens ne travaille pas besoin de quitter. |
Efficacité d'extinction d'incendie | 1. Sur 30 secondes délai avant l'extinction du feu, because it is controlled by a fire alarm panel and set 30 secondes de retard; 2. The fire extinguishing agent is discharged to the protection room, pas pour l'objet de protection directement. | 1. Extinguishing the fire immediately when the fire detection tube detects out fire; 2. Extinguishing the fire immediately when the fire detection tube detects out fire. |
Le coût du système | The system is complex and needs a special cylinder storage room, and also some have piping systems, engineering costs, and maintenance costs are very high. | Le système est simple, does not need a special cylinder store, maximum to reduces engineering cost and maintenance costs. |
From the above chart, we can see that compared with conventional gas fire suppression systems, Dispositif de tube de détection d'incendie, and its system has many advantages.
In practical engineering, we are more consider with 2 facteurs, one Characteristics of a fire protection zone, un autre est l'investissement d'ingénierie et de gestion de l'exploitation et les coûts.
Alors, When the protection zone is large in area or volume and needs to flood the room, use a conventional fire suppression system better, when the protection zone is small, par exemple, an electrical cabinet, or elevator control cabinet, use a fire detection tube as solution because it is easy to install and low in cost.
Un tube de détection d'incendie de couleur rouge est très long, the length is about 25 meters or 30 meters for each device, so one or two fire detection tube devices can make fire protection of several or even tens of electrical cabinets in the hazard, et puis son coût moyen est très faible.
This system has come out of China and now many enterprises both in China and overseas have adopted it as a main fire prevention solution; Some research institutes and government organizations even strongly recommend this product for some specific fields.