A data center is a specific network of devices that collaborate globally, used to transmit, accelerate, display, compute, and store data information on the Internet infrastructure.
With the booming development of the data center industry globally and the rapid growth of the social economy, there will also be more and more data centers.
There are various types of data centers around the world, and firefighting will be a major challenge.
After years of research, researchers in the firefighting industry have found that halon-alternative aerosol fire prevention systems are very suitable fordata centers.
Aerosol safety device model 1000ST is recommended, below is the datasheet of the aerosol-based fire prevention system:
Model Number: 1000ST.
Size of the Product: Φ167*144 millimeters.
Product Gross Weight: 6500 grams.
Product Net Weight: 1000 grams.
Extinguishing Agent Quality: 1000 grams.
Overlay Area: 10 cubic meters.
Injection Time: no more than 30 seconds.
Spray Delay Time: less than 1 second.
Design Density: 100 grams per cubic Meter.
The Starter: UL listed glass bulb from Germany.
Housing Material: 304 stainless steel.
Housing Temperature: Less than 200℃.
Operation Temperature: -40 to +108℃.
Ambient Relative Humidity: ≤95%.
This fire prevention system product automatically detects fires and initiates fire extinguishing without the need for manual operation, making it safe and environmentally friendly to install in a data center.
Moreover, it can also protect small communication and distribution facilities in data centers, such as distribution cabinets and control panels.
It can also protect other similar places, such as substations and power stations.
Aerosol fire prevention system for data center, substation, and other enclosed electrical facilities.
The aerosol fire extinguishing system is a very special fire extinguishing tool that can be used in almost all unmanned fields because it has the following special characteristics:
It is clean and environmentally friendly and is an alternative product to Halon.
This product will not damage the precision instruments in the data center.
Its emissions do not consume oxygen and are non-polluting to the Earth's atmosphere.
It is an automated fire protection system and can work with fire alarm systems.
It can be installed on both walls and ceilings, either vertically or horizontally.
It is based on strontium nitrate as the main oxidant and is the latest fire-extinguishing technology.
No need for yearly inspection and low cost in maintenance.
Its shell is a 304 stainless steel cylinder, without any pressure, very safe, beautiful, and fashionable.