Do all for safety,for a safe world!

Halon-Alternative Aerosol Fire Prevention System

» Products » Minisol Aerosol Fire Extinguisher » Halon-Alternative Aerosol Fire Prevention System
  • Halon-Alternative Aerosol Fire Prevention System

    CATEGORY AND TAGS:
    Minisol Aerosol Fire Extinguisher, Products

    Aerosol fire extinguishing systems can be installed in data centers to protect control cabinets, communication equipment, and electrical equipment.

    enquiry
    • Specifications
    • Characteristics
    • Application
    • More Information

    A data center is a specific network of devices that collaborate globally, used to transmit, accelerate, display, compute, and store data information on the Internet infrastructure.

    With the booming development of the data center industry globally and the rapid growth of the social economy, there will also be more and more data centers.

    There are various types of data centers around the world, and firefighting will be a major challenge.

    After years of research, researchers in the firefighting industry have found that halon-alternative aerosol fire prevention systems are very suitable for data centers.

    Aerosol fire prevention system

     

    Aerosol safety device model 1000ST is recommended, below is the datasheet of the aerosol-based fire prevention system:

    • Model Number: 1000ST.
    • Size of the Product: Φ167*144 millimeters.
    • Product Gross Weight: 6500 grams.
    • Product Net Weight: 1000 grams.
    • Extinguishing Agent Quality: 1000 grams.
    • Overlay Area: 10 cubic meters.
    • Injection Time: no more than 30 seconds.
    • Spray Delay Time: less than 1 second.
    • Design Density: 100 grams per cubic Meter.
    • The Starter: UL listed glass bulb from Germany.
    • Housing Material: 304 stainless steel.
    • Housing Temperature: Less than 200℃.
    • Operation Temperature: -40 to +108℃.
    • Ambient Relative Humidity: ≤95%.

    This fire prevention system product automatically detects fires and initiates fire extinguishing without the need for manual operation, making it safe and environmentally friendly to install in a data center.

    Moreover, it can also protect small communication and distribution facilities in data centers, such as distribution cabinets and control panels.

    It can also protect other similar places, such as substations and power stations.

    Aerosol fire prevention system for data center, substation, and other enclosed electrical facilities.

    The aerosol fire extinguishing system is a very special fire extinguishing tool that can be used in almost all unmanned fields because it has the following special characteristics:

    • It is clean and environmentally friendly and is an alternative product to Halon.
    • This product will not damage the precision instruments in the data center.
    • Its emissions do not consume oxygen and are non-polluting to the Earth's atmosphere.
    • It is an automated fire protection system and can work with fire alarm systems.
    • It can be installed on both walls and ceilings, either vertically or horizontally.
    • It is based on strontium nitrate as the main oxidant and is the latest fire-extinguishing technology.
    • No need for yearly inspection and low cost in maintenance.
    • Its shell is a 304 stainless steel cylinder, without any pressure, very safe, beautiful, and fashionable.
    • Compared with FM200 fire suppression systems, the aerosol system is very simple to install.

    The main application areas of aerosol fire extinguishing systems are as follows:

    • Data processing center.
    • Computer room.
    • Server room.
    • Power generator room.
    • Power distribution room.
    • Genset.
    • Energy Storage Container.

    During storage, handling, and installation processes, the product precautions are as follows:

    • The glass bulb is easy to break due to external force, so use Poly Dragon or foam bag for protection during transportation.
    • After installing the product, the last step is to install the glass ball starter to prevent incorrect activation of the fire extinguisher.
    • The recommended storage temperature for the product should not exceed 40 degrees.
    • Before installation, read the instruction manual to understand installation precautions and steps.

    Enquiry Form ( we will get back you as soon as possible )

    Name:
    *
    Email:
    *
    Message:

    Verification:
    4 + 3 = ?

    Maybe you like also