If we need to explain the feasibility of a Dry Chemical Fire Extinguisher Device for a central control room, then we must start with the definition and function of the central control room itself.
The central control room is not only the center for centralized control of electrical equipment in power plants and substations but also the command center for electricity production and scheduling in the entire plant. It is also a place for human-machine information exchange in monitoring systems.
There are many of electrical equipment in the central control room, such as generators, transformers, DC screens, etc., so the central control room is an area with a high risk of fire.
From the perspective of fire protection requirements, it is necessary to configure the correct fire extinguisher device and alarm devices in the central control room.
At present, many systems can be used in the central control room, including water spray systems, gas suppression systems, aerosol systems, and dry powder fire extinguishing systems. Today we recommend a superfine dry chemical fire extinguisher device.
Specific Parameters of This Super-fine Dry Chemical Fire Extinguisher
The specific parameters and description of the product are as follows:
- Product Name: Ultrafine Pressurized ABC chemical fire extinguisher device.
- Shape: Spherical.
- Surface Color: Red.
- Shell Material: Carton Dioxide or Stainless Steel.
- Hook type: 0 ring.
- Pressure Index: 1.2 to 1.5 Mpa.
- Electric Starting Voltage: DC 3 to 24 volts.
- Starting Current Value: 1A.
- Thermal Start Temperature Value: 175℃ or 300℃.
- Starting sound: less than 120 decibels.
- Retardation Time: less than 1 seconds.
- Fire Extinguishing Time: less than 5 seconds.
- Longest Product Lifecycle: 5 Years.
- More Details: As per the Instruction Manual.
The FM200 fire extinguishing system can also be used in the central control room, but due to the complexity of the FM200 system, some engineering companies choose to install a chemical fire extinguisher instead of FM200 to simplify the installation process.
There are two types of super-fine ABC dry chemical fire extinguishing devices, one is the pressurized type and another is a non-pressurized type.
- The pressurized type fire extinguisher is filled with nitrogen gas as a pressure source to drive the fire extinguishing agent.
- There is a gas-producing agent in the non-pressure storage tank, which is generally pressure-free. When the product is started, the gas-producing agent will push the fire-extinguishing agent out of the nozzle.
Reach us we will explain their differences.