HFC-227ea fire detecting tubes system indirect type, use HFC-227ea agent as fire extinguishing agent, it’s a standalone fire suppression system with multiple functions of:
- 1. Fire Detect.
- 2. Fire Alarm.
- 3. Fire Extinguishing.
Fire Detecting Tube is an innovative fire suppression system, that uses carbon dioxide gas or HFC-227ea gas as a fire extinguishing agent and is simpler and easier than conventional pipeline network CO2 systems or HFC-227ea systems.
Hereby we recommend the indirect type of HFC-227ea fire detecting tube, details as follows:
- Model: WZ-Q/T-12Q.
- Device Discharging Type: Indirect.
- Normal Working Pressure: 5.7 MPa.
- Max Working Pressure: 12.4 to 15 Mpa.
- Min Agent Dosage Per Volume: 0.7 kilograms per cubic meter.
- Fire Detection Tube Max Length: 25 meters.
- Extinguishing Tube Max Length: 12 meters.
Fire Detecting Tube also named "Fire Suppression Sensing Automatic Activation Fire Suppression System", it is made up of fire detecting tube, fire extinguishing agent bottle, Signal feedback device etc
The products has advantages of:
- Do not require any outer power supply.
- no need any special fire detection device.
- Don't require complex equipment and pipeline.
- Easy to install.
- Simple in structure.
- Reliable and durable.
- Collect functions of Fire Alarm, Fire Detecting and Fire Extinguishing.
This system is apply to put out Class A fire, Class B fire, Class C fire, Class E fire.
Mainly apply in the following field:
- Cable Well.
- Cable Tunnel.
- Cable Rack.
- Power Generator Room.
- Power Distribution Room.
- Electronic Equipment Room.
- Television Facilities.
- Data Processing Room.
- Telecommunication Communication Facilities.
- Control Center.
- Health-care Facilities.
- Expensive Industrial Equipment.
- Heavy Duty Equipment.
- Museums.
- Art Gallery.
- Libraries and archives..
- Printing Room.
- Machine Room.
- UPS Power Facilities.
- Oil Storage Field.
- Clean Plant.
Fire Detecting Tube is a metal tube have a certain strength, when filled with pressure it will detect the fire and automatically broke to discharge out fire extinguishing agent or transfer fire alarm signal.
Fire Detecting tube as fire detector element, when the environment temperature arrives at 170±10 degree Celsius, the tube will be automatic melting and the tube will be pressure releasing, container valve will open automatically, and the fire extinguishing agent will discharging out to suppress out fire.
For this product we have some other models:
- WZ-Q/T-6Q (6 kilograms of HFC-227ea agent)
- WZ-Q/T-3Q (3 kilograms of HFC-227ea agent)