Categorieën
- Onze blog (69)
- technologische ondersteuning (18)
Many customers after having a look at our condensed aerosol fire suppression system, toonde veel belangstelling, maar ze wisten niet eens hoe ze onze verschillende modellen en typen moesten kiezen, want voor spuitbussen hebben we drie basisseries, er zijn: vloerstaande serie, wandmontage serie en minisol vaste serie.
The standing series is square and could be red color painted or silver-white color painted, hun grootte is normaal gesproken 400 * 300 * 680 mm en 600 * 300 * 680 mm, or another special design size, met 2.5 kilogram naar 10 kilogram aërosol blusmiddel vulling binnenin, de belangrijkste modellen zijn zoals hieronder::
. AW-QRR2.5LW/S.
. AW-QRR5LW / S.
. AW-QRR7.5LW/S.
. AW-QRR10LW/S.
Zoals we kunnen zien, it just needs to be put in the ground to install, it is large and filled with a large quality aerosol compound in kilograms, so it is suitable to install in some spaces with a volume of more than several tens of cubic meters or for some large projects, and also there must be some leftover space to put the device on corner of the ground, zoals:
. Computerruimtes.
. Telecommunicatie kamers.
. Gegevensverwerkingsruimten.
. Onderstations van transformatoren.
. Kabelkluis, kabelgoot, and cable well.
. National Library.
. Musea.
. Archieven.
. The large size of low and high-voltage power distribution rooms.
. Grote stroomgeneratorruimtes enz.
It is recommended to install it in a bigger space because it is more economical in pricing, Vooral de stroomverdeelruimte, computer Kamer, bibliotheek, museum, etc are more suitable to use this style.
Wall mounted series is cylindrical and could be red color painted or silver white color painted, hun grootte is normaal gesproken een diameter van 300 * 700 mm of een diameter van 300 * 800 mm;, or other special design sizes, met 2.5 kilogram naar 10 kilogram aërosol blusmiddel vulling binnenin, de belangrijkste modellen zijn zoals hieronder::
. AW-QRR5GW/S.
. AW-QRR7.5GW/S.
. AW-QRR10GW/S.
Zoals we kunnen zien, it needs to be installed on the wall or the top ceiling, het heeft de gemiddelde grootte en de kwaliteit van de aerosolverbinding in kilogram, it is also suitable for installation in some spaces with a volume of more than several tens of cubic meters or a large project, it better to install in the site that requires to install on the wall or the ceiling, zoals:
. Computer Kamer.
. Telecommunicatie kamer.
. Transformator kamer.
. Ondergrondse leidingen gallery.
. Stroomverdeelruimte.
. Energieopwekkingsruimte.
. Gegevensverwerkingsruimte enz.
It is recommended to install in the median size of space and install where there is little space left on the ground to put a fire extinguishing device because it is more economical in pricing and space-saving by installing it on the ceiling or the wall.
Especially the underground pipe gallery and wind power energy industry are better to use this kind of.
Minisol vaste serie spuitbussen is also in cylindrical size, het is 304 stainless cylinders in silver white color (roestvrij staal kleur), de maat is erg klein of kleiner, the minimum size is the diameter of 51*95mm and the maximum size is the diameter of 219*295mm, met 0.03 kilogram naar 3 kilogram aërosol blusmiddel vulling binnenin, de belangrijkste modellen zijn zoals hieronder::
. AW-QRR0.03GW / S (30 gram).
. AW-QRR0.06GW / S (60 gram).
. AW-QRR0.1GW / S (100 gram).
. AW-QRR0.15GW / S (150 gram).
. AW-QRR0.2GW / S (200 gram).
. AW-QRR0.25GW/S (250 gram).
. AW-ARR0.3GW / S (300 gram).
. AW-QRR0.5GW/S (500 gram).
. AW-QRR0.75GW/S (750 gram).
. AW-QRR1GW / S (1000 gram).
. AW-QRR1.5GW/S (1500 gram).
. AW-QRR2GW / S (2000 gram).
. AW-QRR2.5GW/S (2500 gram).
. AW-QRR3GW / S (3000 gram).
Omdat:
Omdat het veelzijdig is, flexible, en klein van formaat, people can install it everywhere inside and outside the protection room (beschermingsobject), zoals:
. Telecommunicatie kamers.
. Power transformer rooms.
. Distributing rooms.
. Power-generating rooms.
. Gegevensverwerkingsruimten.
. Ruimte in de elektrische kast.
. Elektrische schakelkast en bord.
. Vehicle auto engine compartments, zoals bussen, auto's, coaches, and trucks.
. Windenergie energiecompartiment.
. CNC-machines, printing machines, Geldautomaten, enzovoort.
For some projects it is very complicated, not only does the room need to be protected but also the electrical cabinet or machines need to be protected as well, in this condition both Floor standing Aerosol (or wall-mounted aerosol) and mini fixed aerosol fire extinguishing devices are required to install.
Bijvoorbeeld, a computer server room is 20 meter lang, 15 meters in width, en 4 meter hoog, er zijn 60 sets of cabinets inside the room and their size are 60 centimeter lang, 50 centimeters in width, en 2 meter hoog, we are planning to design aerosol fire extinguishing device as a fire solution, then we install wall-mounting or floor standing aerosol for the whole room and the Minisol aerosol fire extinguisher for the cabinet, ontwerp details zoals hieronder::
Oke, wanneer mensen onze aerosolproducten installeren voor hun lopende project, ze zullen altijd vragen: “Do you also have a fire alarm system?”, “How can we connect a fire alarm system with your products?”, “do we need to design a fire alarm system together with your aerosol products?” enzovoort.
For these questions, our answer is “Ja”, we can provide fire alarm systems as per clients’ vereisten, but how to design and connect a fire alarm system with our aerosol systems is divided into 2 onderdelen:
Zie onderstaande artikelen:
Mini-aerosolsysteem voor brandbeveiliging met lithiumbatterij voor voertuigen met nieuwe energie
Automatisch aërosolblusapparaat voor schakelkast en behuizing
Aerosol fire extinguisher and suppression system for bank ATMSpeciaal gevaar aerosol brandbeveiligingssysteem voor kritische toepassing
In these articles, there are many installation photos you can see, that all the installed mini aerosol devices work standalone without any power supply and without connecting and designing with fire alarm systems together. (Opmerking: in some vehicle engine rooms if customers have special requirements for installing fire alarm systems, we kunnen ontwerpen om ze ook te gebruiken, for this issue if there is any doubt please contact us for a further discussion).
Some people will say “I just want to have a fire detection to work with your aerosol device, hoe kunnen we deze functie vervullen??”, okay this is easy we have a special fire detection product called “Thermische activering Generator”, and it can detect out fire at its rated temperature 45℃, 70℃, 93℃, 110℃ after detecting out a fire it can activate the Minisol aerosol automatically by sending out a small current, dit zijn de productlinks:
https://www.awarefire.com/stand-alone-system-thermal-activation-generator/
And here is an article to tell you how it connects with aerosol:
Can we make the aerosol fire extinguisher work standalone without any outer power supply
See from the above description we can see that aerosol fire extinguishing systems now is widely used in many industries and have a great marketing prospect all over the world, floor standing aerosol and wall-mounted aerosol are mainly for some projects, and Minisol fixed aerosol is for some small project or some particular special hazard fire protection.
Oke, this article is to tell you about aerosol installation in different places.
If you like this but don’t know how to do it, then contact us we will communicate with you and offer help.
Verwijzing:
Hereby are some international standards/regulations/rules for aerosol fire extinguishing systems:
Standaard voor vaste aërosolbrandblussystemen: NFPA 2010
Brandblussystemen met gecondenseerde aerosol – Vereisten en testmethoden voor componenten en systeemontwerp, installatie, and maintenance – Algemene vereisten