Hebben alle voor de veiligheid,voor een veilige wereld!

Minisol Fire Protection Device for Energy Storage System

» Onze blog » Minisol Fire Protection Device for Energy Storage System

Minisol Fire Protection Device for Energy Storage System

maart 18, 2019

Why recommend Minisol fire protection device for contained energy storage system

In the new energy industry now there is a new thing appeared, we call a “bevatte(gecontaineriseerd) Energieopslagsysteem”, so now a container is not only used to load cargo but also use for energy storage and energy saving.

bevatte(Gecontaineriseerd) energy storage system is made up of an energy storage container, isolatie systeem, ventilatiesysteem, Elektrisch systeem, noodevacuatiesysteem, blussysteem (fire protection device and fire alarm system), and dynamic loop monitoring system.

Inside the storage container room, all these relative electrical systems will require a good fire fighting system to be a fire protection system.

Every contained energy storage system has with super high cost, so it is necessary to install a suitable fire suppression system, en onze minisol aerosol fire protection device is aanbevolen.

OPMERKING: ESS is een afkorting voor Energy Storage Systems, en BESS is een afkorting voor Battery Energy Storage Systems, they include in-building, gecontaineriseerd, en kastsystemen, Een aërosol brandblussysteem is welcome to be installed in battery room fire protection and is very highly effective.

Minisol brandblusapparaat voor ingeperkt energieopslagsysteem

Know something about the Contained Energy Storage System First

ten eerste, Energieopslagcontainer

De energie opslag container room is ontworpen om gemakkelijk te vervoeren en eenvoudig te installeren, inside has ventilation systems, isolatiesystemen, Elektrische systemen, brandbestrijdingssystemen, noodevacuatiesystemen, and dynamic loop monitoring systems, het is met een strikte en redelijke ontwerplay-out;, de beveiliging verbeteren, economische efficiëntie, flexibiliteit van bediening.

It uses good quality steel as material, het is goed geschilderd, anti-corrosie, en met luiken in de hoek.

Normally a total flooding fire suppression system will have to be installed on the wall or the top ceiling of the container room, A gas fire extinguishing system, poeder brandblussysteem, watersysteem, and foam system all can be applied to installed in it, but as a simple and easy-to-install system, we recommend minisol aerosol and hanging type superfijn ABC droog chemisch poeder.

For space-saving suggest installing minisol aerosol fire extinguishing system, and for economic and cost saving recommend the small size of hanging type super-fine ABC dry chemical powder.

Normaal gesproken is het minisol-aerosolsysteem beter aan te brengen en te installeren in dit gebied.

ten tweede, Thermisch isolatiesysteem

EEN thermisch isolatiesysteem is also designed and installed inside the ES container because inside the Energy storage container, there is many of electrical equipment over there and much thermal and heat are produced, so insulation plates and rock wool or polyurethane sandwich panels are always used as thermal insulation materials.

The thermal insulation system should be set on the top, at the bottom, and also on the wall.

Ook, some air-conditioning system is used to control the room temperature.

Ten derde, Ventilatiesysteem

The ventilation system is made up of an air passage, afzuigventilator, luchtinlaat, lamellen, and filter, het is de belangrijkste functie is ventilatie en warmteafvoer;.

This system is always the brother of fire fighting systems and thermal insulation systems, it works together with them to make sure the energy storage system operating well every day.

ten vierde, Elektrisch systeem

The electrical system is het belangrijkste systeem in de ES-container, including a lighting system, bekabelingssysteem, aardingssysteem, schakelsysteem, and energy power distribution system.

Lighting systems use waterproof, moisture-proof, dust-proof lighting to extend its life span.

The wiring system should be set and convenient for maintenance and replacement.

The grounding system uses copper bars, to make electrical cabinets and boxes connect to the ground, om zeker te zijn van een gemakkelijke installatie.

The power distribution system is with many electrical cabinets and control panels, en ook met vele andere elektrische elementen, these electrical elements and equipment are what we need to install a fire extinguishing system.

An emergency evacuation system is also necessary for an energy power storage system, including an emergency exit, ontruimingsslot, noodverlichting, and exit sign.

Ten vijfde, Fire Fighting System (or fire protection device)

A fire fighting system is very necessary for every energy storage system, every energy storage container or electrical cabinet should set a completely good fire suppression system.

Want zonder brandblussysteem, when the energy storage system causes a fire, het zal een groot verlies lijden. Never we should put people’s lives and assets in danger.

Zesde, the Dynamic loop monitoring system

A dynamic loop monitoring system monitors the operating conditions in the container, inclusief: bewaking van temperatuur en vochtigheid, detectie en controle van waterlekkage, veiligheidsbewaking, vermogensregeling, and video monitoring.
By using this system we can monitor the running status in real-time, find the system problem at an earlier time, hint the maintenance staff to take necessary measurements to solve the problem, de kwaliteit van het onderhoud aanzienlijk verbeteren, and improve the reliability and security of operation.

Design Minisol Aerosol Fire Protection Device for the Contained Energy Storage System

With all the above it is better to use a fire suppression system with the following characteristics:

  • As a 20-foot, 40-voet, and 45-foot container room is a very narrow space, better to use a small size of fire extinguishing device for a total flooding fire.
  • Net als in de container zijn enkele kleine elektrische kasten en schakelkasten binnenin geplaatst, better to use a mini-size fire extinguishing device for local application purposes.
  • Omdat de containerruimte beperkt is,, the fire extinguishing device should be easy to install.
  • Ook, the fire extinguishing device must be environmentally friendly, niet corrosief, waterbestendig, nietgeleidend, en onderhoudsvrij.

Our Minisol brand of aerosol fire protection device has the above-described characteristics, and we strongly recommend it for installed energy storage systems.

We have many cases in China to install it in this area (mobiel energieopslagsysteem) in Brazilië, Chili, Europa, Singapore, and Australia some overseas mobile energy storage power stations have already installed this kind of aërosol brandblusapparaat.

In Europa, Amerika, Japan, Korea, South America Area, etc every country and their government are striving to develop new energy and mobile energy storage systems.

Their requirement for new energy and mobile energy storage systems is increasing every year.

New energy power stations like solar power stations, wind power stations, nuclear power stations, and tidal power stations are advocated by the UN United States, Correspondingly energy power storage systems are also recommended and put into use soon.

There is a huge demand for installing our aerosol fire extinguishing systems in these container energy storage systems.

Aërosolbrandblustechnologie is een nieuwe brandbeveiligingstechnologie ter wereld, veel installateurs, engineers, and container producers do not know what is aerosol, how to use and how to install it, we are happy to share the newest aerosol fire suppression technology to whom may concern about it all over the world if any question about this special hazard fire suppression please feel free to let us knows.

thermo bulb aerosol brandblusser generator 4

    Bekijk meer brandblusproducten

    Misschien heb je ook graag