    7-gram aerosol extinguishment, one of the smallest fixed-type suppression systems in the world.

    It can cover about 0.10 cubic meters of space and is an ideal solution for narrow enclosed space fire suppression.

    inquérito
    • Especificações
    • Características
    • Aplicação
    • Mais Informações

    7-gram aerosol extinguishment is almost the world’s smallest fire suppression unit in the world, its size is only a diameter of 40 milímetros, and its height is no more than 20 milímetros, such a small product almost can be installed in any small and narrow space.

    Temos muitos casos de instalação, tal como electric meter boxes, small electrical cabinets, lithium battery cylinders, battery compartments for power exchange cabinets, small switchboards, and high-voltage cable explosion-proof connectors.

    This aerosol extinguishment is an innovative technology in the fire suppression industry because of the following advantages:

    • Funciona automaticamente.
    • It has a very stylish appearance, its cylinder is specially made by one of our skilled technicians who has over 40 years of design experience.
    • The cylinder itself does not carry any pressure.
    • It is a small size, and it can make protection for every small space.
    • Its extinguishing agent is made up of the main oxidants of potassium nitrate and strontium nitrate, que são materiais verdes.

    pyrosol lithium battery aerosol suppression system generator

    Below are the main parameters and datasheet:

    • Número de item: QRR0.007G / S / SA.
    • Especificação: φ40 * H20 mm (tão grande quanto QRR0.012G / S / SA)
    • Mount Hole Spacing: φ4*54 milímetros.
    • Concentração do Produto: Menor que 60 para 100 gramas por m3.
    • Suppression Volume: ≤0,1 metros cúbicos.
    • The rated Temperature of the Thermal Sensing Line is 175℃.
    • Tempo de lançamento: ≤4 segundos.
    • Actuator Current: More than 700mA (Corrente direta).
    • atual segura: ≤150mA (Corrente direta).
    • Electric Start-up Time: Menor que 1 segundos.
    • Ambient Temperature Range: Mínimo -50 ℃, Máximo +95℃.
    • Tempo de serviço: ten to fifteen years.
    • Warranty Period: um ano.
    • Compatibilidade: It can work standalone can work with fire alarm devices, e pode cumprir Thermal Activation Devices.

    The price of aerosol fire extinguishing systems varies according to different order requirements.

    In terms of price, some other competitive products have appeared on the market, como FM200, Tubo de Detecção de Incêndio, Químico seco, etc.

    Contudo, compared to others, aerosols have unique advantages and their fire extinguishing principles are also different, Assim sendo, Aerosol fire extinguishers remain a hot seller on the market.

    There are some other manufacturers of aerosol extinguishing systems on the world market. but we are the only manufacturer that produces generation four (4G) advanced aerosol products based on the newest and innovative aerosol technology.

    We produce an S-type strontium nitrate aerosol extinguishment system, while others produce K-type potassium nitrate aerosol. S-type aerosols are better than K-type aerosols in all aspects.

    This product is becoming more and more popular and some lithium battery suppliers are very interested in it because it has the following features and characteristics:

    • Tamanho pequeno.
    • Lightweight.
    • Economia de espaço.
    • Grande capacidade.
    • Rápido para suprimir o fogo.
    • Cilindro não pressurizado.
    • Fácil de operar e instalar.
    • longa vida útil.
    • Mais importante, isto é CLEAN AGENT, after releasing the smoke-like gas runs out from the nozzle without leaving any residue.

    However aerosol systems also have their disadvantages, isso é: depois de lançar, the cylinder is very hot.

    Assim sendo, please handle it carefully after spraying and wait until its cylinder has cooled down before moving it.

     

    Since it is a popular fire extinguishing product, we can imagine that it can be applied in a lot of places, here we list some application places, but not limited to these places:

    • Painel elétrico.
    • Cabine de controle.
    • Armários de medidores.
    • the battery compartment, especially lithium-ion batteries.
    • Equipamento de controle de turbina eólica.
    • Dispositivo de controle de veículos automotivos.
    • Painéis solares.

    Aerosol fire extinguishers are classified as Class 9.1 Hazardous Goods and therefore need to be handled with care.

    When handling, storing, installing, and debugging, please pay attention to the following matters:

    • Qualquer um (exceto idosos e crianças) can install this product, but should be as per the MANUAL DE INSTALAÇÃO.
    • Não desmonte este dispositivo em nenhum momento, nosso empresa não se responsabiliza por nenhum acidente because of this matter.
    • Please do not touch the hot cylinder immediately after the extinguishing unit is sprayed.
    • Armazene-o em local seco e ventilado, evitar chuva e sol.
    • If you accidentally come into contact with an aerosol compound, em seguida, lave as mãos imediatamente com água.
    • Ao fazer a depuração do sistema, certifique-se de que a energia está desligada, to avoid activation by mistake.

    Pedido de Informação ( nós entraremos em contato o mais breve possível )

    Nome:
    *
    O email:
    *
    mensagem:

    Verificação:
    0 + 8 = ?

    Talvez você gosta também