Condensed Aerosol Fire Suppression for Different Environment

» Nosso blog » Condensed Aerosol Fire Suppression for Different Environment

Condensed Aerosol Fire Suppression for Different Environment

janeiro 10, 2019

Temos três séries de dispositivos de aerossol

Many customers after having a look at our condensed aerosol fire suppression system, showed a lot of interest, but they did even not know how to choose our different models and types because for aerosol products we have three basic series, existem: série de chão, montado na parede série e minisol série fixado.

sistemas de supressão de aerossol estilo chão Pyrogen iguais

primeiramente, the Floor Series of Aerosol Suppression Device

The standing series is square and could be red color painted or silver-white color painted, o seu tamanho é normalmente de 400 * 300 * 680 milímetros e 600 * 300 * 680 milímetros, or another special design size, com 2.5 quilogramas para 10 kg de aerossol de extinção composto de enchimento dentro, os principais modelos são como a seguir:
. AW-QRR2.5LW / S.
. AW-QRR5LW / S.
. AW-QRR7.5LW / S.
. AW-QRR10LW / S.

Como podemos ver, it just needs to be put in the ground to install, it is large and filled with a large quality aerosol compound in kilograms, so it is suitable to install in some spaces with a volume of more than several tens of cubic meters or for some large projects, and also there must be some leftover space to put the device on corner of the ground, tal como:
. salas de informática.
. salas de telecomunicações.
. salas de processamento de dados.
. subestações de transformadores de potência.
. abóbada cabo, trincheira do cabo, and cable well.
. National Library.
. Museus.
. arquivo.
. The large size of low and high-voltage power distribution rooms.
. Grandes salas de geradores de energia etc..

It is recommended to install it in a bigger space because it is more economical in pricing, Especialmente a sala de distribuição de energia, sala de informática, biblioteca, museu, etc are more suitable to use this style.

em segundo lugar, the mounted series of Aerosol Fire Suppression Device

Wall mounted series is cylindrical and could be red color painted or silver white color painted, o seu tamanho é normalmente diâmetro 300 * 700 milímetros ou diâmetro 300 * 800 milímetros, or other special design sizes, com 2.5 quilogramas para 10 kg de aerossol de extinção composto de enchimento dentro, os principais modelos são como a seguir:
. AW-QRR5GW / S.
. AW-QRR7.5GW / S.
. AW-QRR10GW / S.

geradores de extinção de incêndio em aerossol montados na parede

Como podemos ver, it needs to be installed on the wall or the top ceiling, é no tamanho mediano e aerossol grande qualidade composto em quilogramas, it is also suitable for installation in some spaces with a volume of more than several tens of cubic meters or a large project, it better to install in the site that requires to install on the wall or the ceiling, tal como:
. Sala de informática.
. sala de telecomunicações.
. quarto transformador de potência.
. Galeria de tubulação subterrânea.
. sala de distribuição de energia.
. sala de geração de energia.
. ambiente de processamento de dados, etc..

It is recommended to install in the median size of space and install where there is little space left on the ground to put a fire extinguishing device because it is more economical in pricing and space-saving by installing it on the ceiling or the wall.
Especially the underground pipe gallery and wind power energy industry are better to use this kind of.

Em terceiro lugar, Minisol Fixa Série de dispositivo de supressão Aerosol

Minisol Condensed Aerosol Fire Suppression Device Models

Minisol aerossol série fixado is also in cylindrical size, isto é 304 stainless cylinders in silver white color (cor de aço inoxidável), o tamanho é muito pequeno ou menor, the minimum size is the diameter of 51*95mm and the maximum size is the diameter of 219*295mm, com 0.03 quilogramas para 3 kg de aerossol de extinção composto de enchimento dentro, os principais modelos são como a seguir:
. AW-QRR0.03GW / S (30 grama).
. AW-QRR0.06GW / S (60 grama).
. AW-QRR0.1GW / S (100 grama).
. AW-QRR0.15GW / S (150 grama).
. AW-QRR0.2GW / S (200 grama).
. AW-QRR0.25GW / S (250 grama).
. AW-ARR0.3GW/S (300 grama).
. AW-QRR0.5GW / S (500 grama).
. AW-QRR0.75GW / S (750 grama).
. AW-QRR1GW / S (1000 grama).
. AW-QRR1.5GW / S (1500 grama).
. AW-QRR2GW / S (2000 grama).
. AW-QRR2.5GW / S (2500 grama).
. AW-QRR3GW / S (3000 grama).

solução de supressão de incêndio em sistemas de aerossol de minisol

Porque:

  • It is a tiny size product, É versátil e flexível, and it can install everywhere even in small enclosed cabinet spaces by using a special design of installation brackets and screws (sometimes using 3M glue or magnet to install).
  • It is a small compound quality of kilograms, it is suitable to install in narrow spaces, como um gabinete elétrico, Painel de controle, compartimento do motor do veículo automóvel, motor de turbina eólica, and battery box.
  • It also can be applied in some larger spaces, por exemplo, 30-grama, 60-grama, 100-grama, 150 gram are very suitable to install on small electrical boards, 100-grama, 150-grama, 200-grama, 250 gram one are very suitable to install in wind turbine engines space, 250 grama, 500 grama, 750 gram one is very suitable for auto vehicle engine compartment, 1000 grama, 1500 grama, 2000 grama, 2500 grama, 3000 gram one is very suitable for install in the power generator room, sala de distribuição de energia, sala de informática, sala de subestação e quaisquer outros espaços com várias dezenas de volumes em metros cúbicos.

Main Application Range

Como é versátil, flexible, e pequeno em tamanho, people can install it everywhere inside and outside the protection room (objeto de proteção), tal como:
. salas de telecomunicações.
. Power transformer rooms.
. Distributing rooms.
. Power-generating rooms.
. salas de processamento de dados.
. espaço do armário elétrico.
. caixa de controle elétrica e tábua.
. Vehicle auto engine compartments, como ônibus, carros, treinadores, e caminhões.
. compartimento de energia eólica.
. máquinas CNC, printing machines, Caixas eletrônicos, e assim por diante.

Installation Case Analysis

For some projects it is very complicated, not only does the room need to be protected but also the electrical cabinet or machines need to be protected as well, in this condition both Floor standing Aerosol (or wall-mounted aerosol) and mini fixed aerosol fire extinguishing devices are required to install.

Por exemplo, a computer server room is 20 metros de comprimento, 15 metros de largura, e 4 metros de altura, existem 60 sets of cabinets inside the room and their size are 60 centímetro de comprimento, 50 centimeters in width, e 2 metros de altura, we are planning to design aerosol fire extinguishing device as a fire solution, then we install wall-mounting or floor standing aerosol for the whole room and the Minisol aerosol fire extinguisher for the cabinet, detalhes do projeto como abaixo:

  • 1. Calcular o tamanho do quarto, it is 20x15x4 and comes to 1500 metros cúbicos.
  • 2. Confirm how many quality Floor Standing Aerosol (ou parede montada) são necessários para usar na sala, confirmar a qualidade de acordo com esta fórmula:
    https://www.awarefire.com/simple-aerosol-fire-suppression-system-calculation-formula/, aqui nós calculamos para fora é 25 conjuntos de AW-QRR10LW / S (ou AW-QRR10GW / S) é necessária de acordo com a fórmula. (observação: densidade de aplicação de criação é 0.14 quilogramas por metro cúbico).
  • 3. Calcular o tamanho do gabinete, isto é: 0.6×0.5×2 trata de 0.6 metros cúbicos.
  • 4. Confirm which model of Minisol fixed aerosol is required to install inside the server cabinet, aqui usamos AW-QRR0.6GW / S (60 gramas), porque AW-QRR0.6GW / S é para proteção de 0.6 metros cúbicos, and each server cabinet needs to install one set, total 60 conjuntos são necessários.
sistema de supressão de incêndio em aerossol para painel de controle do gabinete elétrico

aerosol fire suppression system for the electrical cabinet control panel and switch box

Supporting and Compatible Facilities and Equipment

OK, quando as pessoas instalar nossos produtos em aerossol para o seu projecto em curso, eles vão sempre perguntar: “Do you also have a fire alarm system?”, “How can we connect a fire alarm system with your products?”, “do we need to design a fire alarm system together with your aerosol products?” etc.

For these questions, our answer is “sim”, we can provide fire alarm systems as per clients’ requisitos, but how to design and connect a fire alarm system with our aerosol systems is divided into 2 peças:

  • Parte 1, If connected with our floor standing or wall mounted aerosol or big size Minisol fixed aerosol fire extinguishing device for total flooding purposes, then it needs to work with the fire alarm system and its components, existem painel de controlo do fogo de gás, detector de fumaça, detector de calor, indicador de liberação de gás, strobe Sonda, sino de alarme de incêndio, porão de emergência / abortar botões, auto / switcher Manual, consulte os artigos de sistema completo extinção de incêndios
  • Parte 2, if direct-to-source then use the small or medium-sized Minisol aerosol extinguishing device and protect the electrical cabinet, compartimento do motor do veículo, wind turbine energy, battery box, or some other small enclosed space or some particular space, then it does not require to have a fire alarm system to work with Minisol aerosol, because the Minisol aerosol is automatic and can be used without any outer power supply.

More Reference Articles

Veja abaixo artigos:
mini sistema de aerossol bateria de lítio de proteção contra incêndio para veículos de energia nova
Dispositivo automático de aerossol de extinção para armário eléctrico e invólucro
Aerosol fire extinguisher and suppression system for bank caixa eletrônicosistema de proteção contra incêndio em aerossol especial para aplicações críticas

In these articles, there are many installation photos you can see, that all the installed mini aerosol devices work standalone without any power supply and without connecting and designing with fire alarm systems together. (Observação: in some vehicle engine rooms if customers have special requirements for installing fire alarm systems, nós podemos projetar para usá-los também, for this issue if there is any doubt please contact us for a further discussion).

Some people will sayI just want to have a fire detection to work with your aerosol device, como podemos cumprir esta função?”, okay this is easy we have a special fire detection product called “Gerador de ativação térmica”, and it can detect out fire at its rated temperature 45℃, 70℃, 93℃, 110℃ after detecting out a fire it can activate the Minisol aerosol automatically by sending out a small current, isto é os links de produtos:
https://www.awarefire.com/stand-alone-system-thermal-activation-generator/

And here is an article to tell you how it connects with aerosol:
Can we make the aerosol fire extinguisher work standalone without any outer power supply

More Detailed Descriptions

See from the above description we can see that aerosol fire extinguishing systems now is widely used in many industries and have a great marketing prospect all over the world, floor standing aerosol and wall-mounted aerosol are mainly for some projects, and Minisol fixed aerosol is for some small project or some particular special hazard fire protection.

OK, this article is to tell you about aerosol installation in different places.

If you like this but don’t know how to do it, then contact us we will communicate with you and offer help.

Referência:
Hereby are some international standards/regulations/rules for aerosol fire extinguishing systems:
Padrão para extinção de fogo com aerossol Sistemas Fixos: NFPA 2010
fogo aerossol condensada sistemas de extinção – Requisitos e métodos de ensaio para componentes e design de sistema, instalação, and maintenance – Requerimentos gerais

    Veja mais produtos de supressão de incêndio