Faça tudo para a segurança,para um mundo mais seguro!

Sistema de supressão de incêndio em salas de TI sem tubulação

» Produtos » Pipeless IT Room Fire Suppression System
  • Sistema de supressão de incêndio em salas de TI sem tubulação

    CATEGORIA E TAGS:
    Produtos
    inquérito
    • Especificações

    Aerosol Generator is a gas-alternative pipeless IT room fire suppression system, because aerosol fire extinguisher not only be able to apply in the whole IT room, but also can be installed inside the electrical cabinets as direct-to-source application.

    In a IT room, many electric cabinets over there, then we can install each cabinets with one units of aerosol extinguisher, por exemplo, one cabinets with vomume of 1.5 cubic meter will require a 150 grams of aeosol generator setted inside, with an automatic activation.

    Avançar, we also need to install larger aerosols in the whole IT room. The generally recommended models are 2500g or 3000g.

    The usual situation is that small aerosols protect small spaces and large aerosols protect large spaces.

    Sistema de supressão de incêndio em salas de TI sem tubulação

    Regardless of the type of aerosol device, their basic parameters are the same, below we list the basic parameters of the aerosol(Minisol).

    Technical Specifications

    • Tipo de Produto: IT Room Fire Suppression System.
    • Fórmula: Strontium and Potassium aerosol.
    • Tipo de ativação: elétrico, thermal, or electric + thermal.
    • Firefighting Flooding Time: dentro 60 segundos.
    • Extinguishing efficiency: 0 para 30 cubic metres.
    • Voltage requirement: 3-24V.
    • Current requirement: roughly 500 mA.
    • Resistance Value Range: 1.0-2.0ó.
    • Product temperature upper limit: less than or equal to 200 ℃.
    • Shell and inner tube material: 304 aço inoxidável.
    • Coolant Material: produtos químicos, ceramic pellets.
    • Vida útil do produto: 10 para 15 anos (depending on ambient temperature and humidity).
    • Temperatura ambiente: -40℃ a + 95 ℃.
    • Humidade relativa: 95 percent relative.
    • Supportted Certificates: CE, ROHS, GL, IP67 and ISO series.

    A number of other types of extinguishing devices can also be used as IT ROOM fire suppression systems, but we believe that the simplest and most practical are aerosols, which have excellent performance indicators in all aspects.

    If you have an IT ROOM and need to install a fire suppression system, we recommend the aerosol system to you.

    Dispositivo de supressão de incêndio em veículos de mineração