A distribution room refers to an indoor distribution area with low-voltage loads, mainly distributing electrical energy to low-voltage users.
There are two types of distribution rooms: high-voltage distribution rooms and low-voltage distribution rooms.
High voltage distribution room generally refers to 6kV -10kV high voltage switchgear room; Low voltage distribution room generally refers to a 400V distribution room with 20kV or 35kV station transformer outgoing lines.
The distribution room is composed of electrical components such as switchgear room, incoming cabinet, metering cabinet, PT cabinet, outgoing cabinet, contact cabinet, isolation cabinet, etc.
Because it is a complex place for electricity distribution, it is usually necessary to configure a reliable and efficient fire extinguishing system.
Temperature-sensitive aerosol Automatic Extinguishing Systems are reliable fire protection systems that could be applied in the power generator rooms and power distribution rooms.
Technical Data of Temperature Sensitive Aerosol Automatic Extinguishing Systems
Here we recommend thermo bulb-style aerosol fire extinguishing generator systems, the following are the parameters of model 1500ST:
- Batch Number: 1500ST, tipo de lâmpada termica.
- Dimensão do produto: Φ0.22*0.205 meter.
- Dosagem de Agente Extintor de Incêndio: 1.5 quilogramas.
- Volume de cobertura: 15.0 metros cúbicos.
- Trigger Temperature: Job Glass Bulb 57℃, 68 ℃, 79℃, 93℃.
- Application Temperature: -40 para +108 graus Celsius.
- Umidade Ambiente: ≤95%.
- Concentração de Projeto: 100g/m3.
- Tempo de extinção de incêndio: 19 segundos.
- Nozzle Temperature During Releasing: Menor que 200 graus Celsius.
- Product Cylinder: 304 aço inoxidável com polimento.
- Peso bruto: 8.4 quilogramas.
- Peso líquido: 1.5 quilogramas.
- Vida útil: 10 anos.
- Classe de fogo: UMA, B, C, E.
- Tempo de entrega: 7 para 15 dias.
- More services: OEM, ODM.
além do que, além do mais, Aerosol Automatic Extinguishing Systems can not only be used in distribution rooms but also in small confined spaces, such as distribution cabinet protection, lithium battery protection, etc. The actual usage needs to be calculated based on the aerosol design formula.
Inovativa automatic aerosol fire extinguishers pode ser capaz de aplicar nos seguintes campos:
- Transportation and Vehicles.
- Setor de energia eólica.
- Mining Equipment and Facilities.
- Indústria de telecomunicações.
- Petróleo e Petroquímica.
- A indústria da construção.
- A indústria metalúrgica.
- As instalações de manufatura.
- salas de informática.
- Salas de distribuição de energia.
- Centros de processamento de dados.
- Turbinas eólicas.
- Salas de armazenamento de energia.
- O offshore.
The product is small but very smart, it can be used in any confined space.
Contact us any time for more information.
1500 gramas de composto aerossol podem cobrir uma área de 15 metros cúbicos de espaço de gabinete, obviamente, este produto é adequado para grandes espaços ou salas grandes.
Ao instalar, certifique-se de que o suporte de instalação esteja firmemente instalado no teto ou na parede para evitar cair e ferir pessoas.
Depois da instalação, verifique imediatamente o circuito do dispositivo aerossol e o circuito do sistema de alarme para garantir que o circuito esteja aberto.
Ao depurar o sistema, use uma lâmpada ou relé para testar primeiro para garantir que não haja problemas com o circuito.
Depois que todos os componentes estiverem instalados, conecte o dispositivo de extinção de incêndio em aerossol sem energia.