Faça tudo para a segurança,para um mundo mais seguro!

Extintor de incêndio com gerador de aerossol térmico para túnel de cabos

» Produtos » Minisol Aerosol Extintor de Incêndio »Extintor de incêndio com gerador de aerossol térmico para túnel de cabos
  • Extintor de incêndio com gerador de aerossol térmico para túnel de cabos

    CATEGORIA E TAGS:
    Minisol Aerosol Extintor de Incêndio, Produtos

    A thermally activated aerosol generator fire extinguisher is a small, inteligente, and automatic fire extinguishing device, which can be applied in underground facilities such as utility cable tunnels, cable tench, and cable trays.

    inquérito
    • Especificações
    • Benefits and Features
    • Application Examples
    • Mais Informações

    A thermal Cord is a sensitive self-combustible wire, é espontâneo, when the environment temperature arrives at its rated activation temperature of 175℃ or 300℃, it will burn up and start the fire extinguisher.

    Cable tunnels are tunnels used for laying cables, which are more prone to fires, and following the requirements of the fire code, suitable fire extinguishing solutions need to be set up in cable tunnels.

    The thermal cord gerador de aerossol extintor de incêndio can be applied in cable tunnels, trincheiras de cabos, and cable trays.

    The structure of cable tunnels is complex and the environment is harsh, so installing an aerosol fire extinguisher is a wise choice because of its special properties listed below:

    • It is the simplest fire-extinguishing system in the world at present.
    • It has waterproof and anti-corrosion functions, making it very suitable for cable tunnels.

    Thermal Aerosol Fire Extinguisher for Cable Well

    Parameters of Aerosol Fire Extinguisher 3000TH

    We can see its benefits for cable tunnels from the following parameters:

    • Unit Model: 3000º, por meio deste “º” significa cabo térmico”.
    • The Diameter is 219 milímetros.
    • The Height is 295 milímetros.
    • extinção de Volume: 30 metros cúbicos.
    • Quality of Powdered Aerosol: 3000 gramas.
    • Thermal Sensing Temperature: 175℃ e 300 ℃.
    • Canister Material: 304 Stainless Steel with artwork of polishing.
    • Peso bruto: 12500 gramas.
    • Unit Weight: 3000 gramas.
    • Tempo de Descarga: Menor que 40 segundos.
    • Temperatura de operação: mínimo -40 ℃, máximo + 108 ℃.
    • Umidade de trabalho: ≤95% non-condensing.
    • Densidade projetado: 100 gramas por metro cúbico.
    • Canister Nozzle Temperature: ≤200 graus Celsius.
    • Propellant Gas: Not have.
    • Operating Pressure: Nenhum.
    • Toxicity: Nenhum.

    It is usually installed on the top or side walls of cable tunnels, with a distance of 5 para 10 meters between devices.

    This product can be compatible with other systems inside cable tunnels, such as detection systems, alarm systems, power systems, etc.

    Many people cannot understand why aerosol fire extinguishing devices can be installed in cable facilities. Please refer to Aerosol Fire Extinguishing Generators Apply In Cable Trench.

    We carefully counted and found that our product has the following benefits and features:

    • Fast speed to extinguish the fire.
    • Eficaz e de alto desempenho, with aerosol powder concentration of 100g/m3.
    • Não eletricamente condutivo.
    • Minimize os danos.
    • Harmless to the human body and animals.
    • Simple to integrate with fire alarm systems.
    • Easy to install and maintenance-free.
    • Clean aerosol powder halon alternative.
    • No ozone depletion, and no global warming.
    • Não tóxico.
    • Piping is not required.
    • Para Classe A, B, C, E, and F total flooding applications.
    • Extremely cost-effective.

    This product not only be applied in cable tunnels, trincheiras de cabos, and cable trays but also has a wider application, por favor, consulte o seguinte:

    • Instalações de telecomunicações.
    • Data centers.
    • Máquina de controle numérico de computador.
    • Compartimento do motor marítimo.
    • Turbinas eólicas.
    • Armazéns e depósitos.
    • Motores de veículos.
    • Painéis elétricos.
    • Armazenamento de líquido inflamável.
    • Generator and compressor rooms and compartments.
    • líquidos inflamáveis ​​e combustíveis.
    • Paint rooms.
    • Battery storage rooms.
    • sala de armazenamento de gás.

    When handling an aerosol fire extinguisher, please note the following important points:

    • Do not disassemble the condensing aerosol generator privately to prevent accidents.
    • Do not deform the product housing.
    • Do not carry out welding or other flammable work in the vicinity of aerosol fire extinguishers.
    • Do not smoke near aerosol fire extinguishers.
    • If an aerosol fire extinguishing device is dropped on the ground during handling or installation, make sure that its ignition device and electrical circuitry are intact.
    • This product is dangerous goods, it should be well protected in the transport process.

    Pedido de Informação ( nós entraremos em contato o mais breve possível )

    Nome:
    *
    O email:
    *
    mensagem:

    Verificação:
    1 + 3 = ?

    Talvez você gosta também