Many customers after having a look at our condensed aerosol fire suppression system, showed a lot of interest, but they did even not know how to choose our different models and types because for aerosol products we have three basic series, det finns: floor standing series, wall mounted series and minisol fixed series.
The standing series is square and could be red color painted or silver-white color painted, their size is normally 400*300*680mm and 600*300*680mm, or another special design size, med 2.5 kilograms to 10 kilograms of aerosol extinguishing compound filling inside, the main models are as below:
. AW-QRR2.5LW/S.
. AW-QRR5LW/S.
. AW-QRR7.5LW/S.
. AW-QRR10LW/S.
Som vi kan se, it just needs to be put in the ground to install, it is large and filled with a large quality aerosol compound in kilograms, so it is suitable to install in some spaces with a volume of more than several tens of cubic meters or for some large projects, and also there must be some leftover space to put the device on corner of the ground, såsom:
. Datorrum.
. Telecommunication rooms.
. Databehandlingsrum.
. Power transformer substations.
. Cable vault, kabeldike, and cable well.
. National Library.
. Museer.
. Arkiv.
. The large size of low and high-voltage power distribution rooms.
. Large power generator rooms etc.
It is recommended to install it in a bigger space because it is more economical in pricing, Especially the power distributing room, computer room, bibliotek, museum, etc are more suitable to use this style.
Wall mounted series is cylindrical and could be red color painted or silver white color painted, their size is normally diameter 300*700mm or diameter 300*800mm, or other special design sizes, med 2.5 kilograms to 10 kilograms of aerosol extinguishing compound filling inside, the main models are as below:
. AW-QRR5GW/S.
. AW-QRR7.5GW/S.
. AW-QRR10GW/S.
Som vi kan se, it needs to be installed on the wall or the top ceiling, it is in median size and large aerosol compound quality in kilograms, it is also suitable for installation in some spaces with a volume of more than several tens of cubic meters or a large project, it better to install in the site that requires to install on the wall or the ceiling, såsom:
. Datorrum.
. Telekommunikationsrum.
. Power transformer room.
. Underjordiskt rörgalleri.
. Power distributing room.
. Power generating room.
. Data processing room etc.
It is recommended to install in the median size of space and install where there is little space left on the ground to put a fire extinguishing device because it is more economical in pricing and space-saving by installing it on the ceiling or the wall.
Especially the underground pipe gallery and wind power energy industry are better to use this kind of.
Minisol fixed series aerosol is also in cylindrical size, it is 304 stainless cylinders in silver white color (stainless steel color), the size is very small or smaller, the minimum size is the diameter of 51*95mm and the maximum size is the diameter of 219*295mm, med 0.03 kilograms to 3 kilograms of aerosol extinguishing compound filling inside, the main models are as below:
. AW-QRR0.03GW/S (30 gram).
. AW-QRR0.06GW/S (60 gram).
. AW-QRR0.1GW/S (100 gram).
. AW-QRR0.15GW/S (150 gram).
. AW-QRR0.2GW/S (200 gram).
. AW-QRR0.25GW/S (250 gram).
. AW-ARR0.3GW/S (300 gram).
. AW-QRR0.5GW/S (500 gram).
. AW-QRR0.75GW/S (750 gram).
. AW-QRR1GW/S (1000 gram).
. AW-QRR1.5GW/S (1500 gram).
. AW-QRR2GW/S (2000 gram).
. AW-QRR2.5GW/S (2500 gram).
. AW-QRR3GW/S (3000 gram).
Because:
As it is versatile, flexible, and small in size, people can install it everywhere inside and outside the protection room (protection object), såsom:
. Telecommunication rooms.
. Power transformer rooms.
. Distributing rooms.
. Power-generating rooms.
. Databehandlingsrum.
. Electrical cabinet space.
. Electrical control box and board.
. Vehicle auto engine compartments, like buses, cars, tränare, and trucks.
. Wind power energy compartment.
. CNC-maskiner, printing machines, bankomater, och så vidare.
For some projects it is very complicated, not only does the room need to be protected but also the electrical cabinet or machines need to be protected as well, in this condition both Floor standing Aerosol (or wall-mounted aerosol) and mini fixed aerosol fire extinguishing devices are required to install.
Till exempel, a computer server room is 20 meter i längd, 15 meter i bredd, och 4 meter på höjden, det finns 60 sets of cabinets inside the room and their size are 60 centimeters in length, 50 centimeters in width, och 2 meter på höjden, we are planning to design aerosol fire extinguishing device as a fire solution, then we install wall-mounting or floor standing aerosol for the whole room and the Minisol aerosol fire extinguisher for the cabinet, design details as below:
Okay, when people install our aerosol products for their ongoing project, they will always ask: “Do you also have a fire alarm system?”, “How can we connect a fire alarm system with your products?”, “do we need to design a fire alarm system together with your aerosol products?” etc.
For these questions, our answer is “Ja”, we can provide fire alarm systems as per clients’ requirements, but how to design and connect a fire alarm system with our aerosol systems is divided into 2 parts:
See below articles:
Lithium battery fire protection mini aerosol system for new energy vehicles
Automatic aerosol extinguishing device for electrical cabinet and enclosure
Aerosol fire extinguisher and suppression system for bank bankomatSpecial hazard aerosol fire protection system for Critical application
In these articles, there are many installation photos you can see, that all the installed mini aerosol devices work standalone without any power supply and without connecting and designing with fire alarm systems together. (Anmärkning: in some vehicle engine rooms if customers have special requirements for installing fire alarm systems, we can design to use them also, for this issue if there is any doubt please contact us for a further discussion).
Some people will say “I just want to have a fire detection to work with your aerosol device, how can we fulfill this function?”, okay this is easy we have a special fire detection product called “Thermal Activation Generator”, and it can detect out fire at its rated temperature 45℃, 70℃, 93℃, 110℃ after detecting out a fire it can activate the Minisol aerosol automatically by sending out a small current, this is the product links:
https://www.awarefire.com/stand-alone-system-thermal-activation-generator/
And here is an article to tell you how it connects with aerosol:
Can we make the aerosol fire extinguisher work standalone without any outer power supply
See from the above description we can see that aerosol fire extinguishing systems now is widely used in many industries and have a great marketing prospect all over the world, floor standing aerosol and wall-mounted aerosol are mainly for some projects, and Minisol fixed aerosol is for some small project or some particular special hazard fire protection.
Okay, this article is to tell you about aerosol installation in different places.
If you like this but don’t know how to do it, then contact us we will communicate with you and offer help.
Hänvisning:
Hereby are some international standards/regulations/rules for aerosol fire extinguishing systems:
Standard for Fixed Aerosol Fire-Extinguishing Systems: NFPA 2010
Condensed aerosol fire extinguishing systems – Krav och testmetoder för komponenter och systemdesign, installation, and maintenance – General requirements