Gör allt för säkerhets skull,för en säker värld!

Customized car mounted fire extinguisher start button

» Produkter » Tillbehör för brandsläckning » Customized car mounted fire extinguisher start button
  • Customized car mounted fire extinguisher start button

    KATEGORI OCH TAGGAR:
    Tillbehör för brandsläckning

    start button AW-START01 is a special design activation tool, mainly used for starting kinds of vehicle fire extinguishers, including bowl shape super-fine ABC dry chemical powder fire extinguishers, aerosolbrandsläckare, novec 1230 based fire extinguishers,s, etc.

    This accessory not only has the function of starting the fire extinguisher but also has the function of signal feedback.

     

    förfrågan
    • Specifikationer
    • Funktioner
    • Tillämpningsomfång
    • Uppmärksamhet

    Customized car mounted fire extinguisher start button is a fire extinguisher accessory product independently developed by our company, Because our company’s various fire extinguishing systems are widely used in various vehicles, we need to develop such a supporting product.

    This start button has a highly integrated circuit board that integrates start signals and product feedback signals.

    It mainly has two functions, one is to activate the fire extinguisher, and the other is to provide feedback on the spraying status of the fire extinguisher.

    There is also a buzzer on the circuit panel. The main function of the buzzer is to sound an alarm, indicating that a fire has occurred in the car and reminding the driver to take necessary measures as soon as possible.

    Although its size is small, its functions are powerful, Let us introduce its basic parameters and characteristics:

    • Produktnamn: Car mounted fire extinguisher start button.
    • Fungera: for fire extinguisher from the cab.
    • Product Type: Firefighting accessories, automotive accessories.
    • Modell: AW-START01.
    • Dimensionera: 50*25*30mm (LengthxWidthxHeight).
    • Material: ABS plastic.
    • Wire and length: Flame retardant wire and its length is 25cm adjustable.
    • Wire function: Switch pressure and fire extinguisher activation.
    • Interface: Copper or aluminum.
    • Alarm function: Beep alarm.
    • Circuit board: Ja.
    • Launch panel and color: button type, color red.
    • Main application automobile vehicles: FM200 based fire extinguisher, bowl shape bus fire extinguisher, aerosol car fire extinguisher.

    The fire extinguisher start button is an indispensable part of a complete vehicle fire extinguishing system and plays a very important role in the fire extinguishing system, Now let's introduce its characteristics and features:

    • The size is very small, the dimension is 50x25x30mm. det är platsbesparande.
    • Diversified functions, including both startup and feedback functions.
    • Humanized design with beep alarm function.
    • Compatible with various fire extinguishing systems.
    • Reasonable structure, fine workmanship, and reliable quality.

    It normally is used for some kinds of on-road and off-road vehicles, to start the fire extinguishers which are installed in the vehicle's engine compartment.

    below are their main application scope:

    • Bulldozer cab.
    • Excavator cab.
    • Bus cab.
    • Car cab.
    • Truck cab.
    • heavy-duty loader cab.
    • Airline cabin.
    • Railway train cab.
    • High-speed train cab.
    • Agricultural machinery.
    • Other heavy-duty machinery.

    The following precautions need to be noted:

    • Drive voltage 6-24v, maximum allowable starting current 5A.
    • Power status indication function: the green power indicator light comes on after normal power is on.
    • Please connect the power supply to normal power and it is not controlled by the key.
    • Manual fire extinguishing function: When manually extinguishing the fire, open the upper cover, crush the red button cover, and hold for 1-2 seconds to activate the fire extinguishing device.
    • Fire extinguishing feedback function: After the fire extinguishing device automatically sprays, the red indicator light flashes and the buzzer sounds for a long time.
    • Failure protection function: In design, the functional modules are isolated from each other, and the effectiveness of the manual Automatic fire suppression function can be guaranteed even after the switch has a functional failure.
    • After manually starting the fire extinguishing, the red button switch has been broken and cannot be used again. The fire extinguisher and this switch must be replaced immediately.
    • The start switch is a dual-circuit button, and the output must be connected to the device through 2 dedicated lines.
    • The spraying feedback(signal feedback) of the start switch is a dual circuit and must be connected to the device through two dedicated lines.

    Förfrågningsformulär ( vi återkommer så snart som möjligt )

    namn:
    *
    E-post:
    *
    Meddelande:

    Verifiering:
    2 + 5 = ?

    Kanske gillar du också