Gör allt för säkerhets skull,för en säker värld!

Micro Fire-Extinguishing Aerosol Systems for CNC Machines

» Vår blogg » Micro Fire-Extinguishing Aerosol Systems for CNC Machines

Micro Fire-Extinguishing Aerosol Systems for CNC Machines

October 11, 2019

CNC-maskiner short forcomputer numerical control machines, are automated milling devices that make industrial components without direct human assistance.

There are many different types of CNC machines, but the most common ones are milling machines, lathes, and grinders.

dock, the CNC machines are not only very expensive for each device, but also work every 7/24 hours in operation very easy to get a fire and the fire destroys them.
So that the workshop owners are always suffering from a great loss.

Now not only in China but also all over the world showing interest in installing a small size and highly effective fire suppression device inside the CNC machines, one kind of small size aerosol based fire extinguishing device because come into people’s sight.

Analysis of Causes

Why do people like the fire extinguishing aerosol system device in CNC machines, we list out the following points:

  • Point one, We can make the aerosol fire suppression devices in very small sizes, and not take up much space in the CNC machines.
  • Point two, it is a standalone system with fire detection and fire suppression functions, not required to work with any other fire alarm systems like fire control panel, brandvarnare, värmedetektor, gas release indicators, etc.
  • Point three belongs to a new advanced technology that makes it highly effective, rent medel, miljövänlig, and not have a bad effect on machines and equipment.
  • Point four, some other factors, like other gas suppression systems, are very complex and very large.

Feasibility Description of Aerosol Application in CNC Machines

In practice and after many actual tests it proven that the aerosol fire extinguishing system and its device are very suitable for installation in CNC machines.

Inside a CNC machine space, the temperature is always a bit high, and the working temperature of an aerosol fire extinguishing device is normally from -40 till +108 grader Celsius, so an aerosol system is very suitable to install in a CNC machine space.

An Aerosol system is good to install in CNC machines, one method is to use an installation bracket and its screws to fix the aerosol inside the CNC machine space, it could be fixed on the top, or the side, another is to use magnetic and 3M glue to adhere it to the top ceiling or side of the CNC machines.

The Aerosol system works to flood the whole CNC machine spaces to suppress the fire, it runs out of the fog-alike aerosol compound and quickly reaches everywhere in the CNC machine spaces to extinguish the fire.

We kindly recommend thermal cord activation of the aerosol fire extinguishing device eller thermo bulb activation of the aerosol fire suppression generator inside the CNC machine because using them does not require any fire alarm system to work with, and so easy to install.

Aerosol Basic Specification

Aerosol has the following basic specifications:

  • Aerosol fire extinguishing agents are very highly effective.
  • Actual design density: inte mer än 100 gram per kubikmeter
  • Safety distance: 1.5 meters.
  • Discharging time: within 30 sekunder
  • Fire fighting safety distance: 0.3 meters.
  • Livslängd: 10 år
  • Fire suppression type: A, B, C, E, F
  • Piptemperatur: inte mer än 200 grader Celsius (5mm distance from the nozzle)
  • Shall surface temperature: inte mer än 100 grader Celsius.
  • Installation mode: by installation bracket or by magnetic with 3M glue
  • Arbetstemperatur: -40 till +108 grader Celsius.
  • Arbetstemperatur: ≤95 %
  • Working Power: DC 3 till 24 volt (or AC3 to 380 volt).
  • Minimum start current: mer än 250 MA per 5 milliseconds.
  • Maximum safety current: inte mer än 150 MA per minute.

An Example

How we design fire extinguishing aerosol systems in a CNC machine room, hereby we list out an example below:

A compact center-less style internal grinder with a size of 690 mm in length, 670 mm in width, och 450 mm in height requires to design of a small fixed aerosol fire extinguishing device to protect.

för det första, calculate the protection volume of the machine, it is 0.69m*0.67m*0.45m and comes to 0.20 kubikmeter.

För det andra, to choose which quantity of aerosol and which model to install in this machine, we have already calculated out the protection volume is 0.2 kubikmeter, so the required aerosol device can cover this volume, as our aerosol design density is 100 gram per kubikmeter, and our smallest model is 30 gram of aerosol device, so Model Number AW-QH-30TH(or AW-QH-30ST) is needed to design and install in this grinder machine.

So you can see only a small capacity of the aerosol device can be installed inside the expensive grinder machine, so it is cost-effective and workable.

In China, we have installed many aerosol devices inside the CNC machines for many manufacturer companies and small workshops, and also in the overseas market we have many cases if readers of this article have some similar project which will require a fire suppression system to cover the CNC machines, then please feel free to let us knows, we would like to design and service for you.

More Applications for Fire-Extinguishing Aerosol Systems

Aerosol devices not only be able to installed in CNC machines but also can be able to used in some of the following similar spaces:

  • Vehicle engine room spaces.
  • Wind turbine engine room spaces
  • Vessel engine room spaces
  • ATM spaces
  • Electrical Cabinet and Control Panel spaces
  • Some other small enclosure or semi-enclosure spaces.

Conclusion and feedback

Some people do not like to install a small fire suppression device inside the CNC machine the reason is that the machines seldom catch fire or there is zero possibility of catching fire, in their real operation it is true seldom a fire in a CNC machine, but once a CNC gets a fire, then the whole workshop and their equipment and cargo will get destruction in even in one night.

In China in our city there is a block company that produces bus energy that caught fire in one workshop and caused a loss of USD1500000, the cause of the fire is that one milling machine operated for a long time and melted the electrical cable to catch fire, so consider of this are you still think it is not necessary to have a fire extinguishing device installed inside a CNC machines? This is a serious question we need to think about.

aerosol brandsläckningssystem för elskåps manöverpanel

    Se mer av brandsläckningsprodukter

    Kanske gillar du också