FM200 Direct Type Fire Detecting Tube Systems is perfect for fire detecting, fire alarm, and fire extinguishing, working without an outer power supply; compared with cabinet type and pipeline type of fm200 fire suppression system, this fire detecting tube system is much more simple.
FM200 direct-type fire detecting tube systems use HFC-227ea gas the extinguishing agent and a red 6mm diameter fire detection tube as the medium for conveying the extinguishing agent.
This fire extinguishing system is generally used for fire prevention and control of vehicles, distributionsskåp, and mechanical equipment.
The process of making this product is relatively complex:
för det första, it is necessary to make the steel cylinder clear and clean and use specialized equipment to check the airtightness and water pressure tests of the instruments to ensure that there is no risk of leakage in the steel cylinder.
Inspect container valves and other accessories and assemble them.
Use specialized gas tank filling equipment to fill the FM200 gas fire extinguishing agent into the steel cylinder.
Use specialized nitrogen pressurization equipment to fill nitrogen into the steel cylinder.
Further, conduct airtightness and water pressure tests on the steel cylinder to ensure that there is no leakage of the product.
Pack and ship.
During the product assembly process, it is difficult to install the red fire detection tube, so it is required that the installation personnel have good technical skills and always maintain safety awareness.
Parameters of FM200 Direct Type Fire Detecting Tube Systems
Hereby we would like to recommend the direct type of fm200 fire-detecting tube system as following parameters:
Item number.: WZ-Q/T-3Q and WZ-Q/T-6Q.
Device Extinguishing Type: Direct.
Fire Extinguishing Agent Type: HFC-227ea, FK 5-1-12
Fire Fighting Agent Weight: 3±5% kilograms and 6±5% kilograms.
Nominal Working Pressure: 2.5 MPa.
Maximum Working Pressure: 4.2 MPa.
Omgivningstemperatur: -10 to 50℃.
Minimum agent quality per volume: 0.7 kilograms per cubic meter.
Maximum Length of Fire Detecting Tube: 25 meter.
Components and installation materials: fittings, connectors, parenteser.
Other optional components: alarm controller, tryckvakt, signal device, manual actuator, backup power supply, etc.
Installation Accessories: C trip.
Färg: Rödmålad.
It doesn't need a power supply, brandvarnare, or heat detector, and works without the complex pipeline.
use its pressure reservoir, using a pressurized tube and a bottle. cylinder group, detect and extinguish a fire at its early stage.
Rapidly extinguishing the fire.
High in fire extinguishing efficiency, low cost, work automatic and standalone.
Simple and easy to install.
The fire extinguishing agent HFC-227ea isfärglös, tasteless, ODP=0, ALT=0, GWP=0.
Low Toxicity, Icke-frätande, icke ledande, no residue after releasing.
Microwave Equipment Room.
Decimeter Waver Radio Room.
TV Tower Room.
Transformer Room.
UPS Power Supply Room.
Program-controlled exchange room in the communication system.
Electrical Control Room.
Power Plant Control Room.
Electronic Equipment Room.
Computer Room.
Data Processing Room.
Variable Distribution Room.
Kabelbrunn, kabeltunnel, cable rack.
Power generator room and distribution room.
Elevator controller.
Fire Detecting Tube, also named fire detection tube, or fire trace system, is an easy and simple fire suppression system that uses hfc-227ea or co2 gas as a fire extinguishing agent, it is a gas fire suppression system halon-alternative product.
Fire detecting tube system is very suitable for installation inelektrisk cabinets.
Förfrågningsformulär ( vi återkommer så snart som möjligt )