Gör allt för säkerhets skull,för en säker värld!

Introduction of CO2 Carbon Dioxide Fire Suppression System

» Vår blogg » Introduction of CO2 Carbon Dioxide Fire Suppression System

Introduction of CO2 Carbon Dioxide Fire Suppression System

januari 8, 2018

CONCEPTION AND DESCRIPTION

CO2 is a colorless, luktfri, and non-damaging gas that can be used as a fire suppression agent, it suppresses fire mainly by lowering the level of oxygen which supports combustion in protective hazard areas; it is reliable, fast, and highly effective.

CO2 systems can be stored in high-pressure steel cylinders or low-pressure refrigerated tanks, so they can be divided into two types, one is a high-pressure Brandsläckningssystem för koldioxid, and the other is a low-pressure fire suppression system.

The CO2 fire extinguishing system is different from some other gas fire extinguishing systems, because most other gaseous fire systems are only for total flooding, but this carbon dioxide fire suppression system is not only suitable for total flooding but also can apply for local applications.

The Carbon Dioxide system works for fire Class A, B, and C hazards, and it is non-damaging to property and electrically non-conductive.

T can be worked automatically, manuellt, and mechanically. with minimal carbon dioxide agent to extinguish a protected area and no need to clean up.

Det är det a Clean, Green, and Cost Effective fire safety systems

ATTENTION OF CARBON DIOXIDE FIRE SUPPRESSION SYSTEM

As carbon dioxide is chocking gas, it should be used in normally unoccupied hazard locations or make people or personnel not close when it is discharged

MANLY APPLICATIONS

  • Maritime System.
  • Automated storage and retrieval facilities.
  • Research Institute.
  • Datorrum.
  • Data Processing Rooms.
  • Telekommunikationsanläggningar.
  • Government Facilities.
  • Automotive Vehicles.
  • Production and Processing and Printing Facilities.
  • Blast Furnace Indirect Coal Firing Systems and Plant.
  • Liquid Storage Rooms.
  • Wind Turbine Generators.
  • Engine Rooms.
  • Dust Collectors.
  • And many other facilities.
  • Switch Rooms.
  • Museums Rooms.
  • Library Rooms.
  • The archives.
  • Paper Storage Rooms.

ADVANTAGES

  • It is non-conductive and non-corrosive and easy to clean up after discharging
  • ODP=0 (Zero Ozone-layer Depletion Value).
  • Zero Global Warming Potential.
  • Easily Distributed.
  • Cost Effective-low refilling cost
  • Applicable to deep-seated fires.
  • Stored in high-quality spun cylinders.
  • Lätt att installera.
  • Readily Available.
  • Fewer Components.
  • Excellent grade of risk penetration.

MAIN TECHNICAL PARAMETERS

  • Model and Specifications: OME ( Volume of CO2 suppression agent).
  • Storage Pressure of Extinguishing Agent: 40L, 70L, 90L.
  • Maximum Working Pressure: 12.4 Mpa.
  • Working Power: 24 DC.
  • Filling Density of Extinguishing Agent: ≤0.6kg/L.
  • Fire Suppression Ways: Total översvämning.
  • Urladdningstid: inte mer än 60 sekunder.
  • Start-up: Automatisk, Manuell, and Mechanical Emergency Operation.
  • Kör gas: Nitrogen.
  • Filling Pressure of Start-up Driving Gas: 5.7 (6.0 Mpa).
  • Omgivningstemperatur: 0 till +50 grader Celsius.

high pressure co2 fire extinguishing systems

gas co2 waterless fire extinguishing systems test suppression systems co2
on sell china carbon dioxide suppression systems fixed marine co2 fire protection system

    Se mer av brandsläckningsprodukter

    Kanske gillar du också