Minisol Fire Protection Device for Energy Storage System

» Vår blogg » Minisol Fire Protection Device for Energy Storage System

Minisol Fire Protection Device for Energy Storage System

Mars 18, 2019

Why recommend Minisol fire protection device for contained energy storage system

In the new energy industry now there is a new thing appeared, we call aContained(containerized) Energy Storage System”, so now a container is not only used to load cargo but also use for energy storage and energy saving.

Contained(Containerized) energy storage system is made up of an energy storage container, insulation system, ventilation system, electrical system, emergency evacuation system, fire fighting system (fire protection device and fire alarm system), and dynamic loop monitoring system.

Inside the storage container room, all these relative electrical systems will require a good fire fighting system to be a fire protection system.

Every contained energy storage system has with super high cost, so it is necessary to install a suitable fire suppression system, and our minisol aerosol fire protection device is recommended.

ANMÄRKNING: ESS is short for Energy Storage Systems, and BESS is short for Battery Energy Storage Systems, they include in-building, containerized, and in-cabinet systems, En aerosol brandsläckningssystem is welcome to be installed in battery room fire protection and is very highly effective.

Minisol Fire Extinguishing Device for Contained Energy Storage System

Know something about the Contained Energy Storage System First

för det första, Energilagringsbehållare

De energy storage container room is designed to be easy to transport and easy to install, inside has ventilation systems, insulation systems, electrical systems, fire fighting systems, emergency evacuation systems, and dynamic loop monitoring systems, it is with a strict and reasonable design layout, improving the security, economical efficiency, flexibility of operation.

It uses good quality steel as material, it is well painted, anti-corrosion, and with shutters set in the corner.

Normally a total flooding fire suppression system will have to be installed on the wall or the top ceiling of the container room, A gas fire extinguishing system, powder fire suppression system, water system, and foam system all can be applied to installed in it, but as a simple and easy-to-install system, we recommend minisol aerosol and hanging type superfint ABC torrt kemiskt pulver.

For space-saving suggest installing minisol aerosol fire extinguishing system, and for economic and cost saving recommend the small size of hanging type super-fine ABC dry chemical powder.

Normally minisol aerosol system is better to apply and install in this area.

För det andra, Thermal Insulation System

A thermal insulation system is also designed and installed inside the ES container because inside the Energy storage container, there is many of electrical equipment over there and much thermal and heat are produced, so insulation plates and rock wool or polyurethane sandwich panels are always used as thermal insulation materials.

The thermal insulation system should be set on the top, at the bottom, and also on the wall.

Också, some air-conditioning system is used to control the room temperature.

För det tredje, Ventilation System

The ventilation system is made up of an air passage, exhaust fan, air inlet, louver, and filter, it is main function is ventilation and heat dispersion.

This system is always the brother of fire fighting systems and thermal insulation systems, it works together with them to make sure the energy storage system operating well every day.

Fourthly, Electrical System

The electrical system is the most important system inside the ES container, including a lighting system, wiring system, grounding system, switching system, and energy power distribution system.

Lighting systems use waterproof, moisture-proof, dust-proof lighting to extend its life span.

The wiring system should be set and convenient for maintenance and replacement.

The grounding system uses copper bars, to make electrical cabinets and boxes connect to the ground, to make sure of easy installation.

The power distribution system is with many electrical cabinets and control panels, and also with many other electrical elements, these electrical elements and equipment are what we need to install a fire extinguishing system.

An emergency evacuation system is also necessary for an energy power storage system, including an emergency exit, evacuation lock, emergency lighting, and exit sign.

Fifthly, Fire Fighting System (or fire protection device)

A fire fighting system is very necessary for every energy storage system, every energy storage container or electrical cabinet should set a completely good fire suppression system.

Because without a fire suppression system, when the energy storage system causes a fire, it will suffer from a big loss. Never we should put people’s lives and assets in danger.

Sixth, the Dynamic loop monitoring system

A dynamic loop monitoring system monitors the operating conditions in the container, inklusive: monitoring temperature and humidity, water leakage detection and control, security monitoring, power control, and video monitoring.
By using this system we can monitor the running status in real-time, find the system problem at an earlier time, hint the maintenance staff to take necessary measurements to solve the problem, significantly improve the quality of maintenance, and improve the reliability and security of operation.

Design Minisol Aerosol Fire Protection Device for the Contained Energy Storage System

With all the above it is better to use a fire suppression system with the following characteristics:

  • As a 20-foot, 40-foot, and 45-foot container room is a very narrow space, better to use a small size of fire extinguishing device for a total flooding fire.
  • As inside the container some small electrical cabinets and control boxes are set inside, better to use a mini-size fire extinguishing device for local application purposes.
  • As the container space is limited, the fire extinguishing device should be easy to install.
  • Också, the fire extinguishing device must be environmentally friendly, rostfri, water-proof, icke ledande, and maintenance-free.

Our Minisol brand of aerosol fire protection device has the above-described characteristics, and we strongly recommend it for installed energy storage systems.

We have many cases in China to install it in this area (mobile energy storage system) in Brazil, Chile, Europe, Singapore, and Australia some overseas mobile energy storage power stations have already installed this kind of aerosol fire suppression device.

In Europe, Amerika, Japan, Korea, South America Area, etc every country and their government are striving to develop new energy and mobile energy storage systems.

Their requirement for new energy and mobile energy storage systems is increasing every year.

New energy power stations like solar power stations, wind power stations, nuclear power stations, and tidal power stations are advocated by the UN United States, Correspondingly energy power storage systems are also recommended and put into use soon.

There is a huge demand for installing our aerosol fire extinguishing systems in these container energy storage systems.

Aerosol fire extinguishing technology is a new fire protection technology in the world, many installers, engineers, and container producers do not know what is aerosol, how to use and how to install it, we are happy to share the newest aerosol fire suppression technology to whom may concern about it all over the world if any question about this special hazard fire suppression please feel free to let us knows.

thermo bulb aerosol fire extinguisher generator 4

    Se mer av brandsläckningsprodukter

    Kanske gillar du också