Gör allt för säkerhets skull,för en säker värld!

Technical Ways to Start-up Aerosol Protection Systems

» Teknisk support » Technical Ways to Start-up Aerosol Protection Systems

Technical Ways to Start-up Aerosol Protection Systems

maj 26, 2017

5 activation ways to start up our aerosol protection systems successfully

Before the invention of aerosol fire extinguishing products, most of the tanks of fire extinguishing products had a certain storage pressure, and the risk coefficient of explosion was very high.

Vår mini fixed aerosol protection systems fire extinguisher is with innovative aerosol fire extinguishing technology in the world.

Because it not only solves the problem of danger but also solves the problem of installation mode, startläge, and internal structure.

Take the startup mode for example, our mini type of aerosol systems have 3 single ways and 2 combination ways to start up the generator device body.

SINGLE WAY

First Way- Electrical Start-up

The first way is an electrical start-up, we also say electrical activation, this is the most popular start-up method, by inputting a 3-24v DC or 3-220v AC power supply, the generator can be started or activated rapidly and easily; with electrical activation normally accompanied by fire alarm systems including fire control panel, brandvarnare, värmedetektor, manuell utlösningspunkt, alarms and strobe and so on; and use electrical start-up system the generator can send signal back to the fire control systems to make people know where is the fire and which of the devices acts to extinguishing in time.

People always don’t want to connect aerosol systems with any fire alarm systems because it’s very complex, and they ask me what to do.

Our answer is “Ja, we also can help you”, we can only use our new technology of the Thermal Activation Generator (TAD) to help, each aerosol generator accompanied by one piece of Thermal Activation Generator will work.

by using an electrical activation/start-up type the aerosol fire extinguisher can be applied in computer rooms, data processing centers, elgeneratorrum, bibliotek, restauranger, museer, arkiv, and distribution rooms for total flooding, very widely in the application.

Second Way-Thermo Bulb Start-up

The second way är thermo bulb start-up, we also say bulb thermal actuator, this is the most convenient and simple start-up way, only install our bulb thermal actuator on the aerosol protection systems, and then it will work.

thermo glass bulb actuator

The thermal bulb has rated temperatures, there are 57℃, 68℃, 79℃, 93℃, 141℃, and 182℃ available. and normally range of 57℃, 68℃, 79℃, 93℃ is more popular. by using the thermo bulb type the aerosol fire extinguisher can be applied in switchboards, cabinets, control panels, UPS systems, och så vidare, but the thermo bulb type is not very suitable to install in autos and vehicles, because they always getting shocked will break the glass bulbs (Thermo glass).

We use the JOB Thermo bulb as one of our product components, we have long-term cooperation with de JOB group with its head office in Germany.

The third way is Thermal Cord Activation, A Thermal Cord is a self-sensing element, normally the thermal cord has its own rated temperature of 175℃ and 300 ℃, The 175℃ one more popular.

How does the thermal cord type work? it is when the anywhere of the thermal cord gets a fire flame or when the thermal cord senses the environment temperature over 175℃, then it will start to combust itself, burning from the flame point to inside the aerosol generator, and then starting the generator actuator to make aerosol systems works.

COMBINATION WAYS

Out of image, a combination way is to make one or several single ways together to work, vi har 2 combined ways also, normally we use a single way, but for a customer’s special request, we can use the combined way.
Normally our combined ways are the following:

  • 1. Electrical and Thermal Cord, use both electrical and thermal cords to help activate the generator.
  • 2. Electrical and Thermo Bulb (Bulb thermal Actuator), use both the electrical and thermal bulb to activate the generator.
    The above 2 combined ways are multi-function making the activation/start-up of the generator more flexible and steady.

The combination mode is a double insurance. When one start mode fails, the other start mode will work.

No matter use which startup method, the ultimate goal is to achieve functional fire fighting, some people need to automatically detect and extinguish the fire, while others need to manually extinguish the fire.

Kort sagt, we can offer free debugging of any fire extinguishing method.