    Thermo bulb is a temperature-sensitive element that could work with an automatic aerosol fire extinguishing system.

    They work together to form an independent fire extinguishing system without the need for any additional detection system.

    enquiry
    • Specifications
    • Key Benefits
    • Application
    • More Information

    A distribution room refers to an indoor distribution area with low-voltage loads, mainly distributing electrical energy to low-voltage users.

    There are two types of distribution rooms: high-voltage distribution rooms and low-voltage distribution rooms.

    High voltage distribution room generally refers to 6kV -10kV high voltage switchgear room; Low voltage distribution room generally refers to a 400V distribution room with 20kV or 35kV station transformer outgoing lines.

    The distribution room is composed of electrical components such as switchgear room, incoming cabinet, metering cabinet, PT cabinet, outgoing cabinet, contact cabinet, isolation cabinet, etc.

    Because it is a complex place for electricity distribution, it is usually necessary to configure a reliable and efficient fire extinguishing system.

    Temperature-sensitive aerosol Automatic Extinguishing Systems are reliable fire protection systems that could be applied in the power generator rooms and power distribution rooms.

    Temperature Sensitive Automatic Extinguishing Systems

    Technical Data of Temperature Sensitive Aerosol Automatic Extinguishing Systems

    Here we recommend thermo bulb-style aerosol fire extinguishing generator systems, the following are the parameters of model 1500ST:

    • Batch Number: 1500ST, thermo bulb type.
    • Product Dimension: Φ0.22*0.205 meter.
    • Fire Extinguishing Agent Dosage: 1.5 kilograms.
    • Coverage Volume: 15.0 cubic meters.
    • Trigger Temperature: Job Glass Bulb 57℃, 68 ℃, 79℃, 93℃.
    • Application Temperature: -40 to +108 degrees Celsius.
    • Ambient Humidity: ≤95%.
    • Design Concentration: 100g/m3.
    • Fire Extinguishing Time: 19 seconds.
    • Nozzle Temperature During Releasing: Less than 200 degrees Celsius.
    • Product Cylinder: 304 stainless steel with polishing.
    • Gross Weight: 8.4 kilograms.
    • Net Weight: 1.5 kilograms.
    • Life Cycle: 10 years.
    • Fire class: A, B, C, E.
    • Delivery Time: 7 to 15 days.
    • More services: OEM, ODM.

    In addition, Aerosol Automatic Extinguishing Systems can not only be used in distribution rooms but also in small confined spaces, such as distribution cabinet protection, lithium battery protection, etc. The actual usage needs to be calculated based on the aerosol design formula.

    It has the following key benefits:

    • Non-toxic.
    • Non-conductive.
    • Non corrosive.
    • 304 stainless steel cylinder and not have a pressurized cylinder to work.
    • No need for yearly maintenance and inspection.
    • Suitable for any terrible environment.
    • Fire extinguishing efficiency is very high and very rapid to suppress fire.
    • Innovative aerosol technology, better than other gas fire suppression systems.
    • Compact and easy to install, even you can even DO IT YOURSELF to install it.

    Innovative automatic aerosol fire extinguishers could be able to apply in the following fields:

    • Transportation and Vehicles.
    • Wind power industry.
    • Mining Equipment and Facilities.
    • Telecommunication industry.
    • Petroleum and Petrochemical.
    • The construction industry.
    • The metallurgy industry.
    • The manufacturing facilities.
    • Computer rooms.
    • Power distribution rooms.
    • Data processing centers.
    • Wind turbines.
    • Energy storage rooms.
    • The offshore.

    The product is small but very smart, it can be used in any confined space.

    Contact us any time for more information.

    1500 grams of aerosol compound can cover an area of 15 cubic meters enclosure space, obviously this product is suitable for big space or big room.

    When installing, ensure that the installation bracket is firmly installed on the ceiling or wall to avoid falling off and injuring people.

    After installation, promptly check the circuit of the aerosol device and the circuit of the alarm system to ensure that the circuit is open.

    When debugging the system, use a light bulb or relay for testing first to ensure that there are no problems with the circuit.

    After all components are installed, connect the aerosol fire extinguishing device without power.

    Enquiry Form ( we will get back you as soon as possible )