Do all for safety,for a safe world!

Aerosol Fire Extinguishing Generator

» Products » Minisol Aerosol Fire Extinguisher » Aerosol Fire Extinguishing Generator
  • Aerosol Fire Extinguishing Generator

    CATEGORY AND TAGS:
    Minisol Aerosol Fire Extinguisher, Products

    Automatic fire detection, automatic fire suppression aerosol fire extinguishing generator - 500 grams dual start aerosol units for large-scale fire protection.

    Model AW-2500E/ST.

    enquiry
    • Specifications
    • Main Features
    • Product Application
    • Helpful Information

    The Aerosol fire extinguishing generator has become a popular fire extinguishing device in small and special spaces due to the establishment of standards worldwide.

    There are ISO 15779, EN15276, and KIWA standards in the European Union, and UL 2775 and NFPA 2010 standards in the United States.

    There is a GA499.1-2010 standard in China, and in other countries, they also have national standards for aerosol fire extinguishing systems.

    So aerosol fire extinguishing generators have become popular worldwide.

    glass bulb temperature sensitive fire extinguisher

    Configuration Parameters of Aerosol Fire Extinguishing Generator

    The automation convenience of this product also adds value to its use, Take the example of a 2500-gram dual start product (electric and thermo glass bulb start), The following are the specific configuration parameters of the product:

    • Product Name: 2500 gram dual start aerosol fire extinguishing generator.
    • Start mode: Thermo glass bulb together with electric start.
    • Capacity: 2500 grams.
    • Diameter: 22 centimeters.
    • Height of Product: 26.5 centimeters.
    • Electric starting parameters: 3 to 24 VDC, 1 to 2 Ω, 0.25 to 1 ampere.
    • Glass Bulb Startup Parameters: 57℃, 68℃, 79℃, 93℃.
    • Fire Extinguishing Agent Type and Content: Strontium 50%-60%, Potassium 10%-20%.
    • Protective Volume: 25 cubic meters.
    • Shell Materials: 304 stainless steel.
    • Cooling method: Physical cooling of ceramic particles.
    • Fire extinguishing method selection: fully submerged, some spaces can be partially submerged.
    • Installation Method: Double-sided adhesive installation or screw bracket installation.
    • Packaging: foam board, white box, carton, non-fumigation wooden case.
    • Attachment: Instruction manual, hardware accessories.
    • Operating conditions: -40℃ to +70℃, 98% non-condensing relative humidity.
    • Certification: CE, ROHS, GL, IP67, CNAS, CCS.

    2500 grams of aerosol is the most commonly installed product in large spaces, and many large-scale projects require this product, such as generator rooms, distribution rooms, etc.

    It has stable performance and high fire extinguishing efficiency.

    If you have a large-scale project that requires the installation of an aerosol fire extinguishing system, we strongly recommend this aerosol.

    For more models of the Minisol product line, please refer to the Minisol category.

    aerosol fire extinguisher in cranes

    We have finished introducing the parameters and main features of the product in the previous column. Now, let's introduce the key features of this product:

    • Product dual start, ensuring 100% startup mode.
    • Multiple temperatures to choose from in automatic start mode, 57℃, 68℃, 79℃,93℃, we can also customize the startup temperature specifically.
    • The aviation plug for electric starting is made of stainless steel or titanium alloy, which is of very high quality. The aviation plug has a stable current and supports tens of thousands of plug-and-unplug actions.
    • The product startup line has high quality and the shell is highly insulated, so there is no need to worry about electric shock and electromagnetic induction hazards.
    • The glass ball probe is a high-quality probe, using high-quality probes from Germany's Jiubao, and is a world brand certified by UL.
    • The product manufacturing process has undergone waterproof treatment and is an IP67-grade product, which is supported by testing reports.
    • The product saves space by installing a bracket on the top of the defense zone, without taking up any remaining space.

    This product is wildly popular worldwide not only because of its characteristics but also because of its wide range of applications.

    Next, let's list where it can be used:

    • Computer room.
    • Data processing room.
    • Energy storage containers.
    • Data processing room.
    • Wind farm.
    • Power grid.
    • Shipping vessel.
    • Tunnel.
    • High and low voltage distribution room.
    • Diesel generator room.
    • Central control room.
    • Communication center.
    • Engine Bay and Passenger Bay.

    The thermo glass bulb is very dangerous, so the following precautions should be taken:

    • Please do not install it on the aerosol fire extinguisher body before use.
    • Special protection is also required during transportation. Please use pearl cotton to protect the glass bulbs from being damaged by handlers.
    • Don't let children play with glass bulb heads.
    • Do not install in indoor areas where the temperature is higher than the rated temperature of the thermo glass bulbs.

    Enquiry Form ( we will get back you as soon as possible )

    Name:
    *
    Email:
    *
    Message:

    Verification:
    3 + 5 = ?

    Maybe you like also