Thermal Aerosol Generator Fire Extinguisher for Cable Tunnel

» Products » Minisol Aerosol Fire Extinguisher » Thermal Aerosol Generator Fire Extinguisher for Cable Tunnel
  • Thermal Aerosol Generator Fire Extinguisher for Cable Tunnel

    CATEGORY AND TAGS:
    Minisol Aerosol Fire Extinguisher, Products

    A thermally activated aerosol generator fire extinguisher is a small, smart, and automatic fire extinguishing device, which can be applied in underground facilities such as utility cable tunnels, cable tench, and cable trays.

    enquiry
    • Specifications
    • Benefits and Features
    • Application Examples
    • More Information

    A thermal Cord is a sensitive self-combustible wire, it is spontaneous, when the environment temperature arrives at its rated activation temperature of 175℃ or 300℃, it will burn up and start the fire extinguisher.

    Cable tunnels are tunnels used for laying cables, which are more prone to fires, and following the requirements of the fire code, suitable fire extinguishing solutions need to be set up in cable tunnels.

    The thermal cord aerosol generator fire extinguisher can be applied in cable tunnels, cable trenches, and cable trays.

    The structure of cable tunnels is complex and the environment is harsh, so installing an aerosol fire extinguisher is a wise choice because of its special properties listed below:

    • It is the simplest fire-extinguishing system in the world at present.
    • It has waterproof and anti-corrosion functions, making it very suitable for cable tunnels.

    Thermal Aerosol Fire Extinguisher for Cable Well

    Parameters of Aerosol Fire Extinguisher 3000TH

    We can see its benefits for cable tunnels from the following parameters:

    • Unit Model: 3000TH, hereby “TH” means thermal cord”.
    • The Diameter is 219 millimeters.
    • The Height is 295 millimeters.
    • Extinguishing Volume: 30 cubic meters.
    • Quality of Powdered Aerosol: 3000 grams.
    • Thermal Sensing Temperature: 175℃ and 300℃.
    • Canister Material: 304 Stainless Steel with artwork of polishing.
    • Gross Weight: 12500 grams.
    • Unit Weight: 3000 grams.
    • Discharge Time: Less than 40 seconds.
    • Operation Temperature: minimum -40℃, maximum +108℃.
    • Working Humidity: ≤95% non-condensing.
    • Designed Density: 100 grams per cubic meter.
    • Canister Nozzle Temperature: ≤200 degrees Celsius.
    • Propellant Gas: Not have.
    • Operating Pressure: None.
    • Toxicity: None.

    It is usually installed on the top or side walls of cable tunnels, with a distance of 5 to 10 meters between devices.

    This product can be compatible with other systems inside cable tunnels, such as detection systems, alarm systems, power systems, etc.

    Many people cannot understand why aerosol fire extinguishing devices can be installed in cable facilities. Please refer to Aerosol Fire Extinguishing Generators Apply In Cable Trench.

    We carefully counted and found that our product has the following benefits and features:

    • Fast speed to extinguish the fire.
    • Effective and high performance, with aerosol powder concentration of 100g/m3.
    • Not electrically conductive.
    • Minimize damage.
    • Harmless to the human body and animals.
    • Simple to integrate with fire alarm systems.
    • Easy to install and maintenance-free.
    • Clean aerosol powder halon alternative.
    • No ozone depletion, and no global warming.
    • Non-toxic.
    • Piping is not required.
    • For Class A, B, C, E, and F total flooding applications.
    • Extremely cost-effective.

    This product not only be applied in cable tunnels, cable trenches, and cable trays but also has a wider application, please refer to the following:

    • Telecommunications facilities.
    • Data centers.
    • Computer numerical control machine.
    • Marine engine compartment.
    • Wind turbines.
    • Warehouses and storage rooms.
    • Vehicle engines.
    • Electrical panels.
    • Flammable liquid storage.
    • Generator and compressor rooms and compartments.
    • Flammable and combustible liquids.
    • Paint rooms.
    • Battery storage rooms.
    • Gas storage room.

    When handling an aerosol fire extinguisher, please note the following important points:

    • Do not disassemble the condensing aerosol generator privately to prevent accidents.
    • Do not deform the product housing.
    • Do not carry out welding or other flammable work in the vicinity of aerosol fire extinguishers.
    • Do not smoke near aerosol fire extinguishers.
    • If an aerosol fire extinguishing device is dropped on the ground during handling or installation, make sure that its ignition device and electrical circuitry are intact.
    • This product is dangerous goods, it should be well protected in the transport process.