Many customers after having a look at our condensed aerosol fire suppression system, showed a lot of interest, but they did even not know how to choose our different models and types because for aerosol products we have three basic series, var: ayaklı serisi, duvara monte seri ve minisol sabit seri.
The standing series is square and could be red color painted or silver-white color painted, boyutları normalde 400*300*680mm ve 600*300*680mm'dir., or another special design size, ile 2.5 kilogram 10 İçine kilogram aerosol söndürücü bileşik dolgu, ana modeller aşağıdaki gibidir:
. AW-QRR2.5LW/S.
. AW-QRR5LW/S.
. AW-QRR7.5LW/S.
. AW-QRR10LW/S.
Gördüğümüz gibi, it just needs to be put in the ground to install, it is large and filled with a large quality aerosol compound in kilograms, so it is suitable to install in some spaces with a volume of more than several tens of cubic meters or for some large projects, and also there must be some leftover space to put the device on corner of the ground, gibi:
. bilgisayar odaları.
. Telekomünikasyon odaları.
. Veri işleme odaları.
. Güç trafosu trafo merkezleri.
. Kablo kasası, kablo çıkıntısı, and cable well.
. National Library.
. Müzeler.
. arşiv.
. The large size of low and high-voltage power distribution rooms.
. Büyük jeneratör odaları vb..
It is recommended to install it in a bigger space because it is more economical in pricing, Özellikle güç dağıtım odası, bilgisayar odası, kütüphane, müze, etc are more suitable to use this style.
Wall mounted series is cylindrical and could be red color painted or silver white color painted, boyutları normalde 300*700mm çapında veya 300*800mm çapındadır, or other special design sizes, ile 2.5 kilogram 10 İçine kilogram aerosol söndürücü bileşik dolgu, ana modeller aşağıdaki gibidir:
. AW-QRR5GW/S.
. AW-QRR7.5GW/S.
. AW-QRR10GW/S.
Gördüğümüz gibi, it needs to be installed on the wall or the top ceiling, kilogram olarak orta boy ve büyük aerosol bileşik kalitesindedir., it is also suitable for installation in some spaces with a volume of more than several tens of cubic meters or a large project, it better to install in the site that requires to install on the wall or the ceiling, gibi:
. Bilgisayar odası.
. telekomünikasyon odası.
. Güç trafosu odası.
. Yeraltı boru galeri.
. Güç dağıtım odası.
. Güç üreten oda.
. Veri işleme odası vb..
It is recommended to install in the median size of space and install where there is little space left on the ground to put a fire extinguishing device because it is more economical in pricing and space-saving by installing it on the ceiling or the wall.
Especially the underground pipe gallery and wind power energy industry are better to use this kind of.
Minisol sabit seri aerosol is also in cylindrical size, bu 304 stainless cylinders in silver white color (paslanmaz çelik rengi), boyut çok küçük veya daha küçük, the minimum size is the diameter of 51*95mm and the maximum size is the diameter of 219*295mm, ile 0.03 kilogram 3 İçine kilogram aerosol söndürücü bileşik dolgu, ana modeller aşağıdaki gibidir:
. AW-QRR0.03GW/S (30 gram).
. AW-QRR0.06GW / S (60 gram).
. AW-QRR0.1GW / S (100 gram).
. AW-QRR0,15GW/S (150 gram).
. AW-QRR0.2GW / S (200 gram).
. AW-QRR0,25GW / S (250 gram).
. AW-ARR0.3GW/S (300 gram).
. AW-QRR0.5GW/S (500 gram).
. AW-QRR0,75GW/S (750 gram).
. AW-QRR1GW / S (1000 gram).
. AW-QRR1.5GW/S (1500 gram).
. AW-QRR2GW/S (2000 gram).
. AW-QRR2.5GW/S (2500 gram).
. AW-QRR3GW / S (3000 gram).
Çünkü:
Çok yönlü olduğu için, flexible, ve boyut olarak küçük, people can install it everywhere inside and outside the protection room (koruma nesnesi), gibi:
. Telekomünikasyon odaları.
. Power transformer rooms.
. Distributing rooms.
. Power-generating rooms.
. Veri işleme odaları.
. Elektrik dolabı alanı.
. Elektrik kontrol kutusu ve kartı.
. Vehicle auto engine compartments, like buses, arabalar, antrenörler, and trucks.
. Rüzgar enerjisi enerji bölmesi.
. CNC makineleri, printing machines, ATM'ler, ve bunun gibi.
For some projects it is very complicated, not only does the room need to be protected but also the electrical cabinet or machines need to be protected as well, in this condition both Floor standing Aerosol (or wall-mounted aerosol) and mini fixed aerosol fire extinguishing devices are required to install.
Örneğin, a computer server room is 20 metre uzunluğunda, 15 metre genişliğinde, ve 4 yükseklik metre, var 60 sets of cabinets inside the room and their size are 60 santimetre uzunluğunda, 50 centimeters in width, ve 2 yükseklik metre, we are planning to design aerosol fire extinguishing device as a fire solution, then we install wall-mounting or floor standing aerosol for the whole room and the Minisol aerosol fire extinguisher for the cabinet, aşağıdaki gibi tasarım detayları:
Tamam, insanlar devam eden projeleri için aerosol ürünlerimizi kurduğunda, her zaman soracaklar: “Do you also have a fire alarm system?”, “How can we connect a fire alarm system with your products?”, “do we need to design a fire alarm system together with your aerosol products?” vb.
For these questions, our answer is “Evet”, we can provide fire alarm systems as per clients’ Gereksinimler, but how to design and connect a fire alarm system with our aerosol systems is divided into 2 parçalar:
Aşağıdaki makalelere bakın:
Yeni enerji araçları için lityum pil yangın koruma mini aerosol sistemi
elektrik kabini ve muhafaza için otomatik aerosol yangın söndürme aygıtı
Aerosol fire extinguisher and suppression system for bank ATMKritik uygulama için özel tehlike aerosol yangın koruma sistemi
In these articles, there are many installation photos you can see, that all the installed mini aerosol devices work standalone without any power supply and without connecting and designing with fire alarm systems together. (düşünce: in some vehicle engine rooms if customers have special requirements for installing fire alarm systems, onları kullanmak için de tasarlayabiliriz, for this issue if there is any doubt please contact us for a further discussion).
Some people will say “I just want to have a fire detection to work with your aerosol device, bu işlevi nasıl yerine getirebiliriz?”, okay this is easy we have a special fire detection product called “Termal Aktivasyon Jeneratör”, and it can detect out fire at its rated temperature 45℃, 70℃, 93℃, 110℃ after detecting out a fire it can activate the Minisol aerosol automatically by sending out a small current, ürün linkleri bu:
https://www.awarefire.com/stand-alone-system-thermal-activation-generator/
And here is an article to tell you how it connects with aerosol:
Can we make the aerosol fire extinguisher work standalone without any outer power supply
See from the above description we can see that aerosol fire extinguishing systems now is widely used in many industries and have a great marketing prospect all over the world, floor standing aerosol and wall-mounted aerosol are mainly for some projects, and Minisol fixed aerosol is for some small project or some particular special hazard fire protection.
Tamam, this article is to tell you about aerosol installation in different places.
If you like this but don’t know how to do it, then contact us we will communicate with you and offer help.
Referans:
Hereby are some international standards/regulations/rules for aerosol fire extinguishing systems:
Sabit Aerosol Yangın Söndürme Sistemleri için Standart: NFPA 2010
Yoğunlaştırılmış aerosol yangın söndürme sistemleri – Bileşenler ve sistem tasarımı için gereksinimler ve test yöntemleri, Kurulum, and maintenance – Genel Gereksinimler