The large capacity of condensed aerosol fire system grenades is a viable fire protection solution for electronic computer rooms.
The electronic computer room is normally made up of the primary machine room, temel çalışma odası, first-category auxiliary room, second-category auxiliary room, vb.
Electronic computer rooms should be set on the second or third floor of multistory buildings or high-rise buildings.
We should choose a location as a computer room that keeps away from dust, harmful gas, and fire, özellikle yangından kaçınmak için, we should choose the most suitable fire suppression systems.
After selective selection, we found that the condensed aerosol fire system and the alarm system were the optimal combination of solutions.
We recommend an aerosol grenade model 3000E to install in the electronic computer room, its basic specifications are as follows:
Specification and Model: 3000E.
Boyut: Φ218*294 milimetre.
Koruma Alanı: 30 metreküp.
Mass of Aerosol Agents: 3000 gram.
Başlangıç modu: Elektrik (elektronik aktivasyon).
Silindir Malzeme: 304 stainless steel with silver-white color.
Sealing Film Material: Aluminum foil.
Product Protection Grade: IP67.
Aerosol Agent Color: kahverengi veya sarı.
Gross Weight of Product: 12500 gram.
Spraying Time of Fire Extinguishing Agent: 38 saniye.
Yaşam döngüsü: 10 yıl.
Yangın Söndürme Tipi: A sınıfı yangın, B ateş, C yangın, D fire, ve F ateşi.
Condensed aerosol fire systems have unique advantages:
3000 gram aerosol jeneratörü kapsayabilir 30 cubic meters of each device, so it can be able to apply in a computer room as a total flooding fire suppression solution.
304 Paslanmaz çelik silindir, so it is waterproof and dustproof, we have done an IP67 test report, which certifies that our aerosol extinguishing grenade is water and dust-proof.
The aerosol mass is compact and condensed, and the aerosol device is small in size, and to be installed in narrow spaces on the wall or on the ceiling.
The Aerosol compound is strontium nitrate, dünyanın en yeni aerosol yangın söndürme teknolojisi olan, after release it causes little residue, so it will not damage the computer equipment in the protective room.
Aerosol devices not only can be installed in the room but also in server racks, and computer cabinets.
Below is a relative place where these aerosol extinguishing units can also apply:
Veri işleme odası.
Sunucu odası.
telekomünikasyon odası.
Veri merkezi.
Kontrol panelleri.
Elektrik dolapları.
Jeneratör odaları.
Güç dağıtım odaları.
Ulaşım Hakkında
1. Each device is put into a white or color box with poly-foam or pearl cotton as protection.
2. Every one or two or four inner cartons are put into a brown color double-layer corrugated box, ve özel koruma için, bir sürü kargo için, we usually also use a fumigation wooden case to take the load.
Bakım Hakkında
Bu ürün kompakttır ve basınçsızdır.
Yıllık muayene gerektirmez.
Bakımda düşük maliyet.