    The start button, minisol fire extinguisher, and power supply are capable of forming the most basic fire extinguishing unit, This system is simple, practical, and can be applied to other fields.

    We can design and optimize the configuration plan according to the actual requirements.

     

    soruşturma
    • Özellikler
    • Ana Özellikler
    • Ana Uygulamalar
    • Diğer Daha Fazla Bilgi

    How to make a fire protection solution for rolling stock”? This is the main topic we need to discuss today.

    vagon is all the engines and carriages that are used on a railway, it bears the important task of people’s travel and freight transportation and is an important component of the national economy.

    The cost of manufacturing rolling stock is high because the government requires every component to be safe, stable, and of high quality.

    şüphesiz, the engine of rolling stock is the most expensive and technologically advanced core component, its safe operation is related to people’s travel safety and timeliness, Especially in terms of fire prevention, a complete fire extinguishing system needs to be installed around the engine to detect and extinguish fires, extinguishing them in the early stages.

    Due to the limited space of rolling stock, a fire extinguishing system with a simple structure and easy installation will be the most popular system. we can provide a simple fire protection solution for the rolling stock, We can achieve this goal by using a start button (with pressure switch function), a Minisol fire extinguisher, and an external power supply or battery.

    A brief introduction to the entire recommended fire protection system components is as follows:

    Components 1: Başlama butonu (Fire Protection Solution Accessory)

    Our engineers have specially designed this Start Button, it not only has a start function but also has a buzzer and feedback function. It connects the external power supply and product feedback cable.

    Its size is very small, but its functions are very powerful.

    Components 2: Power supply or Battery

    It provides a starting power source for the fire extinguisher, and only a small current can start the fire extinguisher. Genel olarak, a power supply of 3-24V is sufficient to drive a fire extinguisher.

    Components 3: Minisol Fire Extinguisher

    It is a very important component because it extinguishes fires and protects rolling stock engines. It not only does not damage the engine but also can quickly and efficiently extinguish fires in the early stage.

    Çalışma prensibi

    • When the driver finds a fire in the rolling stock, he can press down the start button in the cabin, to start the minisol fire extinguisher.
    • After the fire extinguisher receives the start order from the start button, The fire extinguisher starts to operate, and the clean extinguishing agent runs out from the nozzle. Bu durumda, there is no need to press the start button manually).
    • When we press the start button, current flows from the power supply end to the fire extinguisher end, to activate the fire extinguisher.
    • During the spraying of the aerosol fire extinguishers, the signal-receiving transmitter installed inside the extinguisher will emit a signal to the start button, causing the buzzer on the start button to start emitting an alarm sound.

    The main features of this system are simplicity and ease of use, ek olarak, it has other benefits, listed below:

    • The black start button is composed of a circuit board and has powerful functions. It not only starts the fire extinguisher but also has a signal feedback function. The panel is equipped with a buzzer.
    • For power suppliers, they can either directly connect to the power supply on the motor vehicle, or connect to an external 3-24V power supply or battery.
    • Aerosol extinguishers have two starting functions, thermal start and electric start. thermal start belongs to the category of automatic start, and electric start needs to be connected to the power supply or battery supply.
    • The product nozzle is located at the bottom and does not require a pipe network. The extinguishing agent sprayed is small smoke particles that can reach any space in the engine compartment.
    • Aerosol agents are cleaning agents that do not cause damage to electronic components in the engine compartment.
    • Three sets of components are combined to form a complete and simple locomotive fire extinguishing system, which is simple and durable.
    • The product has a lifespan of up to 10 years and is easy to replace after 10 yıl.

    A simple fire extinguishing system is always popular because it is very practical, This fire extinguishing system is mainly used in various industrial and commercial places, as well as government agencies. Hereby we list some main application areas:

    • Locomotives.
    • Military Shelters.
    • Askeri radar istasyonu.
    • Vending machines.
    • Farming machines.
    • Numerically controlled machine.
    • Otomobil araçları.
    • Vessel and boat engine.
    • Electric bus.
    • Elektrikli araba.
    • Electric bus.
    • Elektrik motorları.
    • Electric forklifts.
    • Rüzgar türbini motor kaportaları.
    • Madencilik ekipmanı.
    • Mobile relay equipment.
    • Combine harvester.
    • Central blood station facilities.
    • Ağır iş ekipmanı.
    • Pump station suppression.

    Please note the following when installing a complete system:

    • birinci olarak, it is necessary to carefully read the instruction manual, verify the product list, and check if the materials and accessories are complete; If there are any unclear points, it is necessary to consult the dealer or direct manufacturer promptly.
    • Pay attention to correct wiring and construct according to the wiring drawings provided by the manufacturer. It is best to arrange mature technical personnel for installation and construction work.
    • The glass panel on the start button is disposable. If there is no fire, please do not press the start button.
    • The aerosol fire extinguisher is installed with a fixed bracket and clamp, with the nozzle facing the area prone to ignition.

    Talep Formu ( Biz en kısa sürede size geri alacak )

    isim:
    *
    E-posta:
    *
    Mesaj:

    Doğrulama:
    1 + 9 = ?

    Belki de ister